Crystal Vision
Installation
Remote 5 – 8 Lower frame connections (26-way high density D-Type plug/socket)
Pin
number
Remote 5 function
(socket)
Remote 6 function
(plug)
Remote 7 function
(socket)
Remote 8 function
(plug)
1
+5.5V nom. dc out Slot 17 GPI ‘e’
+5.5V nom. dc out Slot 19 GPI ‘e’
2
Frame GND
Slot 17 GPI ‘f’
Frame GND
Slot 19 GPI ‘f’
3
Slot 21 GPI ‘a’
Slot 18 GPI ‘e’
Slot 23 GPI ‘a’
Slot 20 GPI ‘e’
4
Slot 18 GPI ‘a’
Slot 18 GPI ‘f’
Slot 20 GPI ‘a’
Slot 20 GPI ‘f’
5
Slot 17 GPI ‘a’
Relay close on fault,
PSU3
Slot 19 GPI ‘a’
Relay close on fault,
PSU1
6
Slot 17 GPI ‘b’
Frame GND
Slot 19 GPI ‘b’
Frame GND
7
Slot 14 GPI ‘a’
RX+ bus RS422
Slot 16 GPI ‘a’
N/C
8
Slot 13 GPI ‘a’
TX- RS422 o/p
Statesman
Slot 15 GPI ‘a’
N/C
9
Slot 13 GPI ‘b’
TX+ RS422 o/p
Statesman
Slot 15 GPI ‘b’
N/C
10
Slot 22 GPI ‘a’
Slot 14 GPI ‘e’
Slot 24 GPI ‘a’
Slot 16 GPI ‘e’
11
Slot 22 GPI ‘b’
Slot 14 GPI ‘f’
Slot 24 GPI ‘b’
Slot 16 GPI ‘f’
12
Slot 21 GPI ‘b’
Slot 21 GPI ‘e’
Slot 23 GPI ‘b’
Slot 23 GPI ‘e’
13
Slot 18 GPI ‘c’
Slot 21 GPI ‘f’
Slot 20 GPI ‘c’
Slot 23 GPI ‘f’
14
Slot 18 GPI ‘b’
Relay common,
PSU3
Slot 20 GPI ‘b’
Relay common,
PSU1
15
Slot 17 GPI ‘c’
+5.5V nom. dc out
Slot 19 GPI ‘c’
N/C
16
Slot 14 GPI ‘b’
RX- bus RS422
Slot 16 GPI ‘b’
N/C
17
Slot 14 GPI ‘c’
TX+ bus RS422
Slot 16 GPI ‘c’
N/C
18
Slot 13 GPI ‘c’
RX+ RS422 i/p
Statesman
Slot 15 GPI ‘c’
N/C
19
Slot 22 GPI ‘c’
Slot 13 GPI ‘e’
Slot 24 GPI ‘c’
Slot 15 GPI ‘e’
20
Slot 22 GPI ‘d’
Slot 13 GPI ‘f’
Slot 24 GPI ‘d’
Slot 15 GPI ‘f’
21
Slot 21 GPI ‘d’
Slot 22 GPI ‘e’
Slot 23 GPI ‘d’
Slot 24 GPI ‘e’
22
Slot 21 GPI ‘c’
Slot 22 GPI ‘f’
Slot 23 GPI ‘c’
Slot 24 GPI ‘f’
23
Slot 18 GPI ‘d’
Relay open on fault,
PSU3
Slot 20 GPI ‘d’
Relay open on fault,
PSU1
24
Slot 17 GPI ‘d’
N/C
Slot 19 GPI ‘d’
N/C
25
Slot 14 GPI ‘d’
TX- bus RS422
Slot 16 GPI ‘d’
N/C
26
Slot 13 GPI ‘d’
RX- RS422 i/p
Statesman
Slot 15 GPI ‘d’
N/C
Note:
The total current available from the 5.5V DC outputs is limited to approximately 1.0
amp from the upper frame and 1.0 amp from the lower frame. Note the upper frame and
lower frame DC outputs are separately fused with thermal auto resetting fuse.
To maintain EMC compliance only good quality screened cable assemblies should be
used.
All comms connections are common to all remotes and RJ45s.
Indigo 4 CoolFlow User Manual R1.7
11