2.2 General Purpose Interface (GPI)
The external GPI control lines 'a' to 'f' at the frame remote connectors may be used to
control the DDAA132P remotely with (say) remote switches emulating some of the front
panel switches. The GPI lines are normally pulled up on board to +5V via 10k
Ω
and will
withstand up to +35V.
GPI connections
Open
Connect to ground
‘a’
No setup
Adds 7.5 IRE of setup to Y & reduces Y gain
as required. Only affects 525 line output.
‘b’
625 line if manual standard selected on
jumper PL8
525 line if manual standard selected on
jumper PL8
‘c’
Blank PAL lines 7 to 22 & 320 to 335,
NTSC lines 10 to 20 & 273 to 282
Unblank PAL lines 7 to 22 & 320 to 335,
NTSC lines 10 to 20 & 273 to 282
‘d’
See table below
See table below
‘e’
See table below
See table below
‘f’
See table below
See table below
GPI test pattern select
Composite output
‘d’
‘e’
‘f’
SDI input
Open
Open
Open
SDI input
Open
Open
Closed
SDI input
Open
Closed
Open
SDI input
Open
Closed
Closed
Pluge
Closed
Open
Open
Vertical edge markers
Closed
Open
Closed
Luma/chroma ramp
Closed
Closed
Open
EBU colour bars
Closed
Closed
Closed