21
Installation, Operation & Service Manual– Form 1707001 Rev1
f. Display PCB is defective or
has wiring problems.
Water dispenser is
slow
a. The water dispensing tubes
are kinked.
b. The water dispensing valve is
defective.
a. Straighten them.
b. Call service.
Water is leaking
a. The dispenser drip tray is full.
b. The condensate drip tray is
full.
c. The internal water reservoir or
tubes is leaking.
d. The internal water reservoir
water level sensor is defective.
e. The water dispensing valve is
defective.
f. Ice is being melted because of
high freezer temperature.
a. Empty it.
b. Empty it.
c. .Call for service.
d. Call for service.
e. Call for service.
f. Check for power or call for service.
Icemaker evaporator
is iced
a. The freezer door is not closed
properly.
b. The ice chute flap is not closed
properly.
c. Water fill tube is leaking water.
a. Close it.
b. Close it.
c. Align the fill tube in the fill cup.
Both freezer and
icemaker evaporators
are iced
a. The defrost solenoid valve is
defective or has wiring
problems.
b. The defrost drip tray heater is
broken or has wiring problems.
c. The evaporator fan is broken.
d. The defrost sensor is
defective.
e. The freezer sensor is
defective.
a. Call for service.
b. Call for service.
c. Call for service.
d. Call for service.
e. Call for service.
Codes
Codes
Faults
Response
E01
Defrost temperature probe is defective
Call Service
E02
Freezer temperature probe is defective
Call Service
E03
Hot water temperature probe is defective
Turn off “Hot” & Call
Service
E04
Hot water temperature is extremely high
Turn off “Hot” & Call
Service
E05
Water level float switch is defective
Turn off “Hot” & Call
Service
E06
Freezer door is open
Close Door
E07
Icemaker is not functioning properly
Call Service
E08
Display Board or Control Board
Call Service
E09
Freezer temperature is extremely high
Disconnect Power and
Call Service
E10
Freezer temperature is high
Disconnect Power and
Call Service
For Filter Alerts: See FLr section on page 11.