background image

!

 

20

Below information only the handset will already be paired  

Pairing the handset with the gas valve  

Ensure the handset and the gas fire control have good batteries inside and the batteries are 
facing the correct direction (as shown inside the battery compartments).
Ensure the battery contacts and compartments are clean and free from any contamination. 
(The green light on the handset will flash fast when the handset is held (not steady green), 
which shows it is ready to accept a pairing from the gas fire control.
(NOTE: Ensure the small slide switch on the top left of the gas fire control is slid to the right (I) 
position).
Place the handset within a few feet of the fire ( no need to hold it at the time ).
On the gas fire, simultaneously press the hold the  -  and  +  buttons on the gas fire control (i.e. 
not the handset) unit the red light on top left of gas fire control begins to flash rapidly,(this will 
take about 5-8 seconds),  then immediately as the red light starts to flash release the  -  and  +  
buttons and quickly and press the power button  that is underneath them. (Note: This button 
press must be done with 1 second of the red light coming on. If not done quickly enough, then 
the above must be repeated until done correctly).  
When done correctly, you will hear an audible sound from the handset. Immediately pick up and 
grasp the handset as normal to unlock the key pad and then press and hold   the “ set “  button 
for around 3 to 5 seconds.
When you hear several beeps from the handset as the pairing has been confirmed.
You know the pairing has taken as now when holding the handset the green light will be a 
steady green (not flashing when held).
You can now scroll through the settings of the handset adjusting by pr or - to adjust 
each setting and move on when set by pressing the set button once all set keep pressing the 
set button until you leave the set up menu 
More information can be found at  www.crystalfires.co.uk

IMPORTANT USER INFORMATION – AFTER INSTALLATION BY THE ENGINEER , READ 
THIS BEFORE ATTEMPTING TO OPERATE THE FIRE

NOTE: The handset is supplied paired to the Gas Control. Do not alter the pairing. The 
handset is designed to be not too easily operated by accident for safety reasons. If for 
any reason the pairing has been altered, then the handset will not work. The handset 
needs to be reset and paired again.

Содержание CONNELLY GAS STOVE

Страница 1: ...LENTINES BUILDINGS AINTREE RACECOURSE BUSINESS PARK LIVERPOOL L9 5AY THIS APPLIANCE IS CATEGORY I2H FOR USE WITH NATURAL GAS AT A SUPPLY PRESSURE OF 20 mbar G B AND I E INSTALLATION SERVICING BOOK THI...

Страница 2: ...NEY SUITABILITY 3 4 2 0 INSTALLATION 5 2 1 HEARTH 5 2 2 SITING 5 2 3 FLUE CONNECTION 5 2 4 VENTILATION 5 2 5 GAS CONNECTION 6 2 6 FUEL FITTING 7 8 2 7 OPERATING INSTRUCTIONS 9 10 11 12 2 8 SPILLAGE 13...

Страница 3: ...and use regulations or the rules in force failure to do so could lead to prosecution The installer must be gas safe registered The installation must also be in accordance with all relevant parts of t...

Страница 4: ...ensure that the inside of the chimney flue is in good condition along its length and check that there is no leakage of smoke through the structure of the chimney flue during and after the smoke pellet...

Страница 5: ...ould be fitted for protection of young children or elderly or infirm persons The door handle has to be removed to remove the glass allow to cool before removing this as it will become very hot and is...

Страница 6: ...tilation should be in accordance with national regulations in the UK purpose provided ventilation is not normally required BS5871 part 1 and in IE IS813 IE only 2 5 GAS CONNECTION The gas can be made...

Страница 7: ...burner with the mica fill ensuring it is filled to top and evenly spread around Back log can be placed as shown to the left The left of the log to the end of the burner Large log sits into the left c...

Страница 8: ...sits to the front on to the left As shown image left The triple branch log sits on the left side touching the very left side of the first log and the second log As shown to left Final log sits from f...

Страница 9: ...9 Below remote control handset 2 7 OPERATING INSTRUCTIONS Below the gas controls which are situated at the bottom left of the appliance...

Страница 10: ...et The handset also has batteries as shown below It is important that the batteries are replaced at least every 12 months The meaning s of the red indicator on valve and handset Red indicator Meaning...

Страница 11: ...ote This button press must be done with 1 second of the red light coming on If not done quickly enough then the above must be repeated until done correctly When done correctly you will hear an audible...

Страница 12: ...he power symbol button and release immediately when the word pilot comes on to the display at the bottom left as shown about 1 2 seconds The stove will light NOTE Releasing too soon or too long after...

Страница 13: ...res used 3 0 SERVICING INSTRUCTIONS The stove is fitted with a spillage monitoring system consisting of a thermal switch this system is not adjustable and must not be bypassed or put out of action if...

Страница 14: ...TOVE 1 VALENTINES BUILDINGS AINTREE RACECOURSE BUSINESS PARK LIVERPOOL L9 5AY THIS APPLIANCE IS CATEGORY I2H FOR USE WITH NATURAL GAS AT A SUPPLY PRESSURE OF 20 mbar G B AND I E USERS INSTRUCTIONS THI...

Страница 15: ...ut must be in accordance with national regulations in force The fuel should be arranged only as shown in these instructions Should the stove extinguish for any reason do not relight for a minimum of 3...

Страница 16: ...r with the mica fill ensuring it is filled to top and evenly spread around Back log can be placed as shown to the left The left of the log to the end of the burner Large log sits into the left corner...

Страница 17: ...g sits to the front on to the left As shown image left The triple branch log sits on the left side touching the very left side of the first log and the second log As shown to left Final log sits from...

Страница 18: ...18 OPERATING INSTRUCTIONS Below the gas controls which are situated at the bottom left of the appliance Below remote control handset Display handset may be supplied to assist seasonal efficiency...

Страница 19: ...andset The handset also has batteries as shown below it is important the batteries are replaced every 12 months Red indicator Meaning Permanently Lit Valve tried to light but failed and in LOCKOUT E00...

Страница 20: ...ote This button press must be done with 1 second of the red light coming on If not done quickly enough then the above must be repeated until done correctly When done correctly you will hear an audible...

Страница 21: ...he power symbol button and release immediately when the word pilot comes on to the display at the bottom left as shown about 1 2 seconds The stove will light NOTE Releasing too soon or too long after...

Страница 22: ...button and this will put the control into Manual snooze mode The default time period for the snooze time period is 1 00 hour Pressing the set button again will show you the snooze time period remainin...

Страница 23: ...utes and if the set temperature is still too high the pilot will then also extinguish When the set temperature is higher than the actual temperature the fire will automatically light and go to the ful...

Страница 24: ...next time of 09 00 press and release SET change the flashing sun symbol to a flashing moon symbol by pressing and releasing the and buttons then press and release SET again to store the moon setting...

Отзывы: