background image

!

 

15

This stove should not be used for any other purpose than as a room heater and decorative stove, due to its 
newness of materials the stove may give off a slight smell for a period of time after commissioning this is 
quite normal and should clear within a few hours of use  

The installation must be in accordance with the national regulations and must be carried by a qualified 
installer EG: gas safe  
Under no circumstances should the stove be operated with the glass panel damaged broken or missing, all 
surfaces except controls are considered to be working surfaces and will get very hot during and after 
use ,if young children, the elderly or infirm are likely to be near the stove a suitable fireguard to BS8423 
is recommended  

A combustible shelf may be fitted above the stove providing the shelf protrudes less than 150 mm in front 
of the stove and there is 300mm clearance above the top of the stove  
Curtains are not recommended above the stove  
Do not drape clothes or any materials over the stove  

The stove must stand on a non-combustible hearth and be at least 12mm thick and sufficient size to 
accommodate the stove 

No purpose provided ventilation is normally required but must be in accordance with national regulations 
in force  

The fuel should be arranged only as shown in these instructions  

Should the stove extinguish for any reason do not relight for a minimum of 3 minutes 

All surfaces, except the control valve are working surfaces and become very hot in use, they must not be 
touched or any combustible materials be put on them  
It is recommended that a fireguard complying to BS 8423 should be fitted for the protection of young 
children or elderly or infirm persons  
The door handle has to be removed to open the door and get to the glass this is also a working surface 
allow to cool before removing  

This stove should be serviced regularly at least annually  

Only replace ceramic parts or any parts of the fuel bed with parts supplied by the manufacturer for this 
stove do not change the fuel bed layout from the instructions supplied 

The flue will need sweeping periodically  

If the stove fails and the appliance goes to reset the start button will have to be held for 10 seconds to clear 
the remote fault  

THE STOVE IS FITTED WITH A SPILLAGE MONITORING SYSTEM CONSISTING OF A 
THERMAL SWITCH. THIS SYSTEM IS NOT ADJUSTABLE AND MUST NOT BE PUT OUT 
OF ACTION & IF REQUIRED TO BE REPLACED ONLY ORIGINAL MANUFACTURERS 
PARTS MUST BE USED ( IF THE STOVE SWITCHES OFF FOR NO APPARENT REASON 
THE  APPLIANCE SHOULD NOT BE USED UNTIL EXPERT ADVICE IS TAKEN )

Содержание CONNELLY GAS STOVE

Страница 1: ...LENTINES BUILDINGS AINTREE RACECOURSE BUSINESS PARK LIVERPOOL L9 5AY THIS APPLIANCE IS CATEGORY I2H FOR USE WITH NATURAL GAS AT A SUPPLY PRESSURE OF 20 mbar G B AND I E INSTALLATION SERVICING BOOK THI...

Страница 2: ...NEY SUITABILITY 3 4 2 0 INSTALLATION 5 2 1 HEARTH 5 2 2 SITING 5 2 3 FLUE CONNECTION 5 2 4 VENTILATION 5 2 5 GAS CONNECTION 6 2 6 FUEL FITTING 7 8 2 7 OPERATING INSTRUCTIONS 9 10 11 12 2 8 SPILLAGE 13...

Страница 3: ...and use regulations or the rules in force failure to do so could lead to prosecution The installer must be gas safe registered The installation must also be in accordance with all relevant parts of t...

Страница 4: ...ensure that the inside of the chimney flue is in good condition along its length and check that there is no leakage of smoke through the structure of the chimney flue during and after the smoke pellet...

Страница 5: ...ould be fitted for protection of young children or elderly or infirm persons The door handle has to be removed to remove the glass allow to cool before removing this as it will become very hot and is...

Страница 6: ...tilation should be in accordance with national regulations in the UK purpose provided ventilation is not normally required BS5871 part 1 and in IE IS813 IE only 2 5 GAS CONNECTION The gas can be made...

Страница 7: ...burner with the mica fill ensuring it is filled to top and evenly spread around Back log can be placed as shown to the left The left of the log to the end of the burner Large log sits into the left c...

Страница 8: ...sits to the front on to the left As shown image left The triple branch log sits on the left side touching the very left side of the first log and the second log As shown to left Final log sits from f...

Страница 9: ...9 Below remote control handset 2 7 OPERATING INSTRUCTIONS Below the gas controls which are situated at the bottom left of the appliance...

Страница 10: ...et The handset also has batteries as shown below It is important that the batteries are replaced at least every 12 months The meaning s of the red indicator on valve and handset Red indicator Meaning...

Страница 11: ...ote This button press must be done with 1 second of the red light coming on If not done quickly enough then the above must be repeated until done correctly When done correctly you will hear an audible...

Страница 12: ...he power symbol button and release immediately when the word pilot comes on to the display at the bottom left as shown about 1 2 seconds The stove will light NOTE Releasing too soon or too long after...

Страница 13: ...res used 3 0 SERVICING INSTRUCTIONS The stove is fitted with a spillage monitoring system consisting of a thermal switch this system is not adjustable and must not be bypassed or put out of action if...

Страница 14: ...TOVE 1 VALENTINES BUILDINGS AINTREE RACECOURSE BUSINESS PARK LIVERPOOL L9 5AY THIS APPLIANCE IS CATEGORY I2H FOR USE WITH NATURAL GAS AT A SUPPLY PRESSURE OF 20 mbar G B AND I E USERS INSTRUCTIONS THI...

Страница 15: ...ut must be in accordance with national regulations in force The fuel should be arranged only as shown in these instructions Should the stove extinguish for any reason do not relight for a minimum of 3...

Страница 16: ...r with the mica fill ensuring it is filled to top and evenly spread around Back log can be placed as shown to the left The left of the log to the end of the burner Large log sits into the left corner...

Страница 17: ...g sits to the front on to the left As shown image left The triple branch log sits on the left side touching the very left side of the first log and the second log As shown to left Final log sits from...

Страница 18: ...18 OPERATING INSTRUCTIONS Below the gas controls which are situated at the bottom left of the appliance Below remote control handset Display handset may be supplied to assist seasonal efficiency...

Страница 19: ...andset The handset also has batteries as shown below it is important the batteries are replaced every 12 months Red indicator Meaning Permanently Lit Valve tried to light but failed and in LOCKOUT E00...

Страница 20: ...ote This button press must be done with 1 second of the red light coming on If not done quickly enough then the above must be repeated until done correctly When done correctly you will hear an audible...

Страница 21: ...he power symbol button and release immediately when the word pilot comes on to the display at the bottom left as shown about 1 2 seconds The stove will light NOTE Releasing too soon or too long after...

Страница 22: ...button and this will put the control into Manual snooze mode The default time period for the snooze time period is 1 00 hour Pressing the set button again will show you the snooze time period remainin...

Страница 23: ...utes and if the set temperature is still too high the pilot will then also extinguish When the set temperature is higher than the actual temperature the fire will automatically light and go to the ful...

Страница 24: ...next time of 09 00 press and release SET change the flashing sun symbol to a flashing moon symbol by pressing and releasing the and buttons then press and release SET again to store the moon setting...

Отзывы: