1-866-303-4028 Crystal Fire 42435 REV H 4/11/12
Clearances to Combustibles
SIDE WALL
3
Framing and Clearances
Note:
Illustrations reflect typical installations
and are
FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to
scale.
Actual installation may vary due to
individual design preference.
Fire Risk
Provide adequate clearance:
Around air openings
For service access.
Locate appliance away from traffic areas
WARNING
72 inches to overhang
from
top
of metal bowl.
METAL
BOWL
If you are not using an
Outdoor GreatRoom
Company table with
this burner, be sure to
mount to a non-
combustible surface
maintaining at least 8”
to combustible
surfaces and framing
below the surface of
burner.
8”
8”
8”
8”