Black Electrical Cord with NEMA 5
-
15 Plug
end should be plugged into a dedicated 120V
outlet.
Note: GFI outlets are not recommended since
they can trip when compressor cycles on.
¼
”
Braided CO2 Hose with
Stainless Steel ¼
”
Flare nut
end. Connects to CO2 Reg
Hose marked
“
CO2
”
¼
”
Braided Water Inlet hose with
3/8”
push in stem fitting end.
Fits into outlet end fitting of the
50 PSI water pressure reducer.
Hose Marked
“
WATER
”
If unit is supplied with a Clear Overflow vent
hose it should be routed to a floor sink if
accessible and positioned per plumbing
code.
Place the unit in the cabinet space, with at least
4”
of
space behind it for clearance for the trunkline bundle,
connections and chiller vents louvers on the side panels.
Do not block any of the ventilated panels on the chiller.
Install CR
-
TFB1 Fan Box in cabinet at this time if using one.
Locate bundled Electrical cord, Water hose, CO2 hose and
Clear overflow hose coming from the bottom of the chiller
and unwrap them. (some units do not have clear overflow
flow hose, and will drain to the drip pan)
CR
-
TFB1
Optional Accessory
Unwrap Water inlet, CO2 inlet,
Overflow Drain and Electrical