background image

Crysalli Beverage Systems

 

a division of WPD

 

1739 Sabre Street, Hayward, CA 94545

www.crysalli.com

510.732.0100

X0101-B-HEX Faucets

The faucets come with a flow rate 

control valve on each one of them. 

This valve is located on the right side 

of the faucet. It is designed to be 

adjusted and set via a metric 2.5 allen 

hex wrench to a desired flow. Flow is 

typically set based on cup size being 

poured into. Adjustments should be 

made while the faucet handle is held 

open and water flowing, to visually see 

the flow setting. Also fill into the glass 

or carafe you will typically be using to 

judge fill time and minimize splashing. 

The slower you can set the flow of 

sparkling water, the better the bubble 

profile you will get. With the Crysalli 

unit on and CO2 set to 75 PSI, adjust 

the valve to a full flow position, then 

adjust the flow rate from the faucet 

down by turning your wrench within a 

quarter turn.
Once set, tighten the outer ring with 

a wrench to lock the valve in place. 

Lock tight can be used on the threads 

of the outer ring to help keep it tight. 

The valve may need to be periodically 

re-adjusted based on use.

Locking flow control 

faucet Part# X0101-B-HEX
With hex key adjustment

Flow control adjuster

Outer ring

Adjustable hex fitting

Using a 2.5 hex wrench to 

adjust flow rate

Содержание CP2000-CT

Страница 1: ... Sparkling Still Countertop Chiller System CP2000 CT2 CP2000 CT3 or PB Systems Crysalli Beverage Systemsa division of WPD 1739 Sabre Street Hayward CA 94545 www crysalli com 510 732 0100 05162022 Register your product online ...

Страница 2: ...Crysalli Beverage Systemsa division of WPD 1739 Sabre Street Hayward CA 94545 www crysalli com 510 732 0100 This page is intentionally left blank ...

Страница 3: ...ely Install Kit for CP2000 CT2 CT3 or PB Countertop Chiller Systems This Kit is designed to supply you with the fittings parts you may need to complete the install of our Everpure CR 14FC Filter system to a Crysalli Countertop CP2000 CT2 with 3 8 John Guest Water Inlet Fitting Always reference local plumbing codes to determine if a backflow preventer is required and to check the type style of back...

Страница 4: ... high pressure CO2 regulator CR PC160 to CO2 cylinder then connect CO2 line from unit to regulator The CO2 line is the braided hose with a stainless steel nut on the end of it 6 Turn on water Check connections for leaks and flush the water filters 7 Open CO2 by turning knob on tank Adjust regulator between 55 75 PSI And check for leaks 8 Run clear overflow drain hose to floor drain or other waste ...

Страница 5: ...ssure tighten locking nut Set gauge 75 PSI CO2 Pressure to carbonator tank in unit Plastic washer Secure line to regulator by tightening nut Lock nut Adjusting screw CO2 Line from regulator to carbonator tank inside unit Remove lid fill water bath to top of stand pipe Drain hose to floor drain Condensation will build inside unit must drain or unit will overflow Note Carbonation levels will be low ...

Страница 6: ...s or carafe you will typically be using to judge fill time and minimize splashing The slower you can set the flow of sparkling water the better the bubble profile you will get With the Crysalli unit on and CO2 set to 75 PSI adjust the valve to a full flow position then adjust the flow rate from the faucet down by turning your wrench within a quarter turn Once set tighten the outer ring with a wren...

Страница 7: ...n be hazardous if not handled properly Follow all CO2 regulator instructors found with CO2 regulator and other handling instructions from the CO2 tank supplier CR PC160 High Pressure CO2 Regulator 0 160 PSI Attaches to 5 100lb CO2 tanks Set at 75 PSI as a starting point Note Low pressure beer regulators 0 60 PSI will not work properly with Crysalli Fill level gauge Volume of CO2 in tank Tank is em...

Страница 8: ...for the Product Additional expenses including without limitation service travel time overtime or premium labor charges accessing or removing the Product or shipping are the responsibility of the consumer The foregoing limited express warranty shall not apply to costs for 1 periodic or routine maintenance including water filter change outs 2 repair or replacement of the Product or parts due to norm...