EB30-2R OPERATING INSTRUCTIONS
Page 20
Other periodical maintenance
Due to a small number of movable parts it is not necessary, except for tensioning the
chain and inductive switch triggering control, to do any adjustments on the
equipment.
Daily:
Clean the cover plates of the roller units
Inspect and clean the rollers
Weekly:
Check the proximity of the middle metal rollers one at the time. The display
will show the respective Lup and Rup green indicating lights on when this
roller is pressed down. The roller brake tester cannot start unless the middle
metal roller is triggered pressed down.
Twice per year:
Remove all cover plates from the roller units.
Clean the pits from oil and dirt.
Check that the adjustment bolts support the main bearings properly.
Check the motors for oil leakage.
Check that the chain deflection does not exceed 10 mm when pressing by
hand.
Replace the battery in the remote control.
Clean the surfaces of the remote control and the control unit.
Bolt the cover plates back in place.
Perform a full check of all functions.
Yearly:
At least once per year the service organisation should perform the transducer