background image

onlinecomponents.com

Rev. 071311

DC Output SSRs

Panel Mount

This installation sheet includes detailed mounting and wiring instrucions which apply for most Crydom Panel 

Mount DC output SSRs. Be sure to visit the product series' datasheet available at the Crydom website to 

complement this information. If you have questions or need additional information please contact Crydom Tech 

Support.

Lug Terminal

Hardware Kit

Cover

TABLE 1.  Accessories

Thermal Resistance

[ºC/W]

Heat Sink

Part No.

5.0
3.5
3.0
2.7
2.5
2.0
2.0
1.7
1.5
1.2
1.0
0.7
0.5

HS501DR
HS351 / HS351DR
HS301 / HS301DR
HS271 / HS271DR
HS251
HS202 / HS202DR
HS201 / HS201DR
HS172
HS151 / HS151DR
HS122 / HS122DR
HS103 / HS103DR
HS072
HS053

KS100

HK1

TRM1
TRM6

Thermal Pad

HSP1
HSP2

(A)

  See compatible accessories in corresponding datasheet.

(B)

  Load can be wired to either terminal 1 or terminal 2. Proper polarity must be observed all the 

time for the power supply and load with terminal 3 being positive with respect to terminal 4.

(C)

  DC inductive loads must be diode supressed. Diode not included.

MOUNTING INSTRUCTIONS

Mounting on Heat Sink

Mounting on Panel

Choose one of the two mounting options and follow the instructions.

Locate the panel section on which the SSR will be mounted. Panel mount surface must provide 

adequate heat sinking capability, uncoated, clean, flat and preferably aluminum.
Be sure to use a thermal pad or thermal compound between the SSR and the panel.
SSR mounting slots have a diameter of 0.2 in (5.0 mm). Two screws are needed (not included) to mount 

the SSR onto panel. Choose screw length considering the mounting surface and that the SSR baseplate 

thickness is 0.125 in (3.2 mm).
Before applying full torque tighten down both screws until they contact the baseplate. Then, tighten 

them to 20 in-lbs (2.2 Nm).

Select adequate heat sink (see thermal derating curves in product series’ 

datasheet).
Be sure to use a thermal pad or thermal compound between the SSR and the 

selected heat sink.
SSR mounting slots have a diameter of 0.2 in (5.0 mm). Two screws are 

needed to mount the SSR onto heat sink (See fig. 1). Mounting screws are 

sold separately as HK1 and are suitable for all Crydom heat sinks. Otherwise, 

recommended screw size is 8-32 (UNC standard) or M4 (metric). Choose 

screw length considering the mounting surface and that SSR baseplate 

thickness is 0.125 in (3.2 mm). 

fig. 1

  

SSR mounted

on HS053 heat sink

(A)

(A)

Before applying full torque tighten down both screws until they contact the baseplate. Then, tighten 

them to 20 in-lbs (2.2 Nm).
For optimal thermal performance heat sink fins should be oriented vertically to promote natural 

convection airflow.

(B, C)

WIRING DIAGRAMS

Wire Size

Maximum wire size capacity per terminal: Input 1 x 12 AWG (3.3 mm

2

), output 2 x 8 AWG 

(8.4 mm

2

). Choose wire gauge according to actual load current. For larger wire sizes use 

lug terminals (see TABLE 1 for available part numbers).

Connections

Ensure that wires ends are stripped to a minimum length of 0.46 in (11.7 mm) for input 

and 0.49 in (12.5 mm) for output.

Transient Protection

An inductive load will produce harmful transient voltages when it is turned off.  The 

more perfect the switch, the larger the transient voltages.  The MOSFET output is so 

nearly ideal switch that the transient voltages produced by seemingly “non-inductive” 

loads can cause damage if not suppressed.  Diodes should be fast recovery type with 

PIV rated greater than supply voltage.

Terminals

Screw type, finger proof (IP20 only). Input: 6-32, Combo Drive. Output: 8-32, Combo 

Drive. Maximum screw torque is 10 in-lbs (1.1 Nm) on input and 20 in-lbs (2.2 Nm) on 

output.

V

+

+

-

Load

1

4

2+

3+

S O L I D   S T A T E   R E L A Y

OUTPUT

INPUT

1   (–)

2   (+)

4   (– /   )

3   (+ /   )

Load

V

+

+

-

1

4

2+

3+

S O L I D   S T A T E   R E L A Y

OUTPUT

INPUT

4   (– /   )

3   (+ /   )

1   (–)

2   (+)

V

+

+

-

Load

1+

4

2

3+

S O L I D   S T A T E   R E L A Y

OUTPUT

INPUT

1   (+)

2   (–)

4   (– /   )

3   (+ /   )

Load

V

+

+

-

1+

4

2

3+

S O L I D   S T A T E   R E L A Y

OUTPUT

INPUT

4   (– /   )

3   (+ /   )

1   (+)

2   (–)

(A)

b

.  DC

60

 Series Wiring Diagram (only)

a

.  Generic DC Output SSRs Wiring Diagram

AMERICA

        

Sales Support

Tel.: +1 (877) 502 5500

[email protected]

        

Tech Support

Tel.: +1 (877) 702 7700

[email protected] 

EMEA

        

Sales Support

Tel.: +44 (0) 1202 606030

[email protected]

        

Tech Support

[email protected]

ASIA PACIFIC

        

Sales Support

Tel.: +86 (0) 21 6065 6699

[email protected]

       

 Tech Support

[email protected] 

(C)

Please read all mounting instructions before using your DC Output Panel Mount Solid State Relay (SSR).

Important Considerations

Be sure to use input and output voltages within operating ranges.

LED indicates only input status. It does not represent output status.

Отзывы: