background image

Power-Tech Series  Power Amplifiers

Page 8

Reference Manual

2.3 Input Sensitivity Adjustment

The input sensitivity switch inside the amplifier is set to
0.775 volts at the factory.* It can be changed to 1.4 volts
or a voltage gain of 26 dB as follows:

1. Turn off and unplug the amplifier from the AC source.

2. Remove the access cover on the back panel.

3. Locate the labeled access hole for the sensitivity switch.

4. Set the switch to the desired position.

5. Replace the access cover plate.

When set to 26-dB gain, the 

Power-Tech 1 requires a

2.1-volt input, the 

Power-Tech 2 requires a 2.6-volt input

and the 

Power-Tech 3 requires a 3.3-volt input to deliver

full output into an 8-ohm load.

Fig. 2.4  Input Sensitivity Switch

2.4 Additional Load Protection

To protect against excessive power, a fuse can be
added in series with each loudspeaker cable. A single
fuse can protect the entire system, or one can be used
for each driver. High-frequency drivers (tweeters) are
usually more sensitive to large voltage peaks, while low-
frequency drivers (woofers) are typically most sensitive
to the heat from average (RMS) output power. To protect
your tweeters, we recommend that you use a high-speed
instrument fuse like the Littlefuse 361000 series. To
protect your woofers, we recommend using a slow-blow
fuse that more closely represents the thermal response
of your woofer. Use Figure 2.5 to find the correct value for
either type of fuse.

Example: (A) Choose the peak music power for the
loudspeaker (such as 75 watts). (B) Find the
loudspeaker impedance (8 ohms). (C) Draw a line
between points A and B. The line intersects the middle
scale at the correct fuse value (1.5 amps).

2.5 Required AC Mains

All 

Power-Tech amplifiers are shipped with an appropri-

ate line cord and plug. The standard cord and plug for

Fig. 2.5  Loudspeaker Fuse Nomograph

Fig. 2.6  AC Mains Cords and Plugs

each model are listed by country (or region) in
Figure 2.6. When possible, use a power receptacle on
a dedicated circuit, and always make sure it will
provide the right voltage with sufficient current. We do
not recommend operating your amplifier with voltages
greater than 10% above or below the unit’s rated
voltage. For example, if your amplifier is rated for
120 VAC, the line voltage should not exceed 132 VAC.

* Factory setting for international models is 1.4 V.

Содержание POWER-TECH 1

Страница 1: ...1000 U S A Telephone 219 294 8000 Power Tech amplifiers are produced by the Professional Audio Unit of Crown International Inc Trademark Notice Power Tech is a trademark and Amcron Crown IOC and ODEP...

Страница 2: ...3 years from the date of purchase by the original purchaser the warranty period that the new Crown product is free of defects in materials and workmanship We further warrant the new Crown product rega...

Страница 3: ...RE REMOVING BACK PANEL COVER TO ACCESS GAIN SWITCH IMPORTANT THE POWER TECH 1 AND 2 REQUIRE CLASS 2 OUTPUT WIRING THE POWERTECH 3 REQUIRES CLASS 1 WIRING IF USED IN THE BRIDGE MONO OR PARALLEL MONO MO...

Страница 4: ...with the manufacturer s instruc tions 8 Do not install near any heat sources such as ra diators heat registers stoves or other appara tus that produce heat 9 Do not defeat the safety purpose of the po...

Страница 5: ...perfor mance for a wide range of loads Complete protection against shorted outputs mis matched loads overheating input output DC and high frequency overload full internal fault protection Balanced ph...

Страница 6: ...de the outputs are paralleled for twice the current capacity Bridge Mono mode is provided for loads with an impedance greater than 4 ohms Parallel Mono mode should be used with loads of 4 ohms or less...

Страница 7: ...Power Tech Series Power Amplifiers Page 7 Reference Manual Fig 2 3 Three System Connection Methods...

Страница 8: ...lly most sensitive to the heat from average RMS output power To protect your tweeters we recommend that you use a high speed instrument fuse like the Littlefuse 361000 series To protect your woofers w...

Страница 9: ...protection and fuses or circuit breakers to protect the power supplies 3 3 1 ODEP Crown invented ODEP to keep the amplifier working under demanding conditions and to increase output efficiency To do t...

Страница 10: ...draw that exceeds the breaker rating Again this should only be possible when operating outside rated conditions like when the amplifier is used to drive a 1 ohm load or when driving a severely clippe...

Страница 11: ...um level setting Power Tech 1 54 1 12 or 35 dB 0 5 dB at 0 775 volt sensitivity 30 1 12 or 30 dB 1 dB at 1 4 volt sensitivity Power Tech 2 66 1 12 or 36 dB 0 5 dB at 0 775 volt sensitivity 36 1 12 or...

Страница 12: ...el 1 controls are active Channel 2 controls should be turned down and not used Parallel Mono Unbalanced single channel Channel 1 controls are active Channel 2 controls should be turned down and not us...

Страница 13: ...y are typical subject to manufacturing tolerances single channel driven or that they are specified with fuses bypassed Each of these statements effectively removes any performance guarantee In fact so...

Страница 14: ...Power Tech Series Power Amplifiers Page 14 Reference Manual Fig 4 2 Power Tech 2 Minimum Power Matrix Fig 4 3 Power Tech 3 Minimum Power Matrix...

Страница 15: ...ximum power matrices Maximum Power Notes All maximum power specifications are based on 0 5 regulated AC mains with THD of less than 1 0 and an ambient room temperature of 70 F 21 C International units...

Страница 16: ...Power Tech Series Power Amplifiers Page 16 Reference Manual Fig 4 5 Power Tech 2 Maximum Power Matrix Fig 4 6 Power Tech 3 Maximum Power Matrix...

Страница 17: ...em that uses standard XLR connectors It can also be used in systems that need to daisy chain an input signal from one amplifier to another Because the MT XLR connectors are in parallel with the amplif...

Страница 18: ...handle the necessary paperwork and repair Remember to transport the unit in the original factory pack A list of authorized service centers in your area can be obtained from our Technical Support Group...

Страница 19: ...___________________________________________________________________ ______________________________________________________________________________ _____________________________________________________...

Отзывы: