This is the Crown

®

 I-Tech  HD Series offers amazing power, light weight and ease of use for touring sound 

applications. Unlike other amplifiers, it includes onboard high-definition DSP, an LCD control screen, and a built-

in network connection.
Modern power amplifiers are sophisticated pieces of engineering capable of producing extremely high power 

levels. They must be treated with respect and correctly installed if they are to provide the many years of reliable 

service for which they were designed.
In addition, I-Tech Series amplifiers include a number of features which require some expla nation before they can 

be used to their maxi mum advantage.
Please take the time to study this manual so that you can obtain the best possible service from your amplifier.

Get Started

Features

1. 

 Global Power Supply with PFC (Power Fac tor Correction) works anywhere in the world.

2. 

High power density, up to 8000 watts in a 2U chassis.

3. 

Highest output voltage in the industry (200V peak) provides clean transient peaks.

4. 

3rd-generation patented Class I (BCA

®

) cir cuitry couples power 

efficiently to the load and provides low AC current draw.

5. 

Onboard high-definition DSP with 24-bit, 192 kHz Cirrus Logic SHARC A/D 

and D/A converters. Advanced IIR filters and linear-phase FIR filters.

6. 

Pushbutton presets simplify setup. Custom presets for various loudspeakers can be down loaded.

7. 

AES/EBU digital audio input.

8. 

EtherCon

®

 Ethernet con nector for HiQnet™ control or CobraNet digital audio transport. This “Single                          

Plug” connection allows HiQnet protocol and CobraNet digital audio through the same CAT 5 cable.

9. 

Analog and digital thru connectors.

10.  LCD Control Screen is used to adjust the amplifier’s attenuation and muting, configure the amp, set                           

up and view error monitoring, and recall DSP presets to reconfigure the amp for various applications.

11.  Comprehensive array of indicators provide accurate diagnostics: Power, Data, along with Ready,                    

Signal, Clip, Thermal and Fault for each channel.

12.  AC mains indicator in power switch glows green when AC power is present.
13.  Front-panel USB connector accepts a USB drive to transfer presets from the drive to the                                     

amplifier DSP, and vice versa.

14.  Light weight due to aluminum chassis, spe cial internal construction and switching power supply.
15.  Thermal management controller and two dis crete thermal zones with variable-speed fans,                         

forced-air cooling.

16.  Advanced protection circuitry guards against: shorted outputs, DC, mismatched loads,   

               

general overheating, under/over volt age, high-frequency overloads and internal faults.

17.  Three-Year, No-Fault, Fully Transferable Warranty completely protects your investment and guarantees its 

specifications.

Unpack and Install Your Amplifier

When Please unpack and inspect your amplifier for any damage that may have occurred during transit. If damage 

is found, notify the transpor tation company immediately. Only you can ini tiate a claim for shipping damage. 

Crown will be happy to help as needed. Save the shipping carton as evidence of damage for the shipper’s 

inspection. 
We also recommend that you save all packing materials so you will have them if you ever need to transport the 

unit. 

Never ship the unit without the factory pack.

YOU WILL NEED (not supplied):
1. 

Input wiring cables 

2. 

Output wiring cables

3. 

Ethernet cables 

4. 

Rack for mounting amplifier (or a stable surface for stacking)

WARNING: Before you start to set up your amplifier, make sure you read and observe 

the Important Safety Instruc tions found at the beginning of this 

manual.

CAUTION: Before you begin, make sure your amplifier is disconnected from the power 

source, with the power switch in the “off” position and all level controls turned 

completely down (counterclock wise).

Use a standard 19-inch (48.3 cm) equipment rack 

(EIA RS-310B).
You may also stack amps without using a  

cabinet.
NOTE: When transporting, amplifiers should be 

supported at both front and back.

Setup

1.5 In.

3.8 cm

3.5 In.

8.9 cm

 16.2 In.

41.1 cm

48.3 cm 

19 In. 

Magnetic Field

CAUTION! Do not locate sensitive high-gain equipment such as preamplifiers or tape decks directly 

above or below the unit. Because this amplifier has a high power density, it has a strong magnetic 

field which can induce hum into unshielded devices that are located nearby. The field is strongest 

on the right side and right bottom of the amplifier (facing the amplifier). 

If an equipment rack is used, we recommend locating sensitive equipment at least 20 cm 

(8 inches) away from the amplifier.

When using an equipment rack, mount units directly on top of each other. Close any open spaces in rack with 

blank panels. DO NOT block front or rear air vents. The side walls of the rack should be a minimum of two inches 

(5.1 cm) away from the amplifier sides, and the back of the rack should be a minimum of four inches (10.2 cm) 

from the amplifier back panel.

Содержание I-T9000 HD

Страница 1: ...s of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www crownaudio com Trademark Notice Crown...

Страница 2: ...e harmfulinterference and 2 thisdevicemustacceptanyinterference received including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the party...

Страница 3: ...d switching power supply 15 Thermal management controller and two dis crete thermal zones with variable speed fans forced air cooling 16 Advanced protection circuitry guards against shorted outputs DC...

Страница 4: ...bel If you are unsure of the output voltage of your AC mains please consult your electrician Packed with your I Tech amplifier is a clip that retains the power cord so it can t pull out accidentally 1...

Страница 5: ...d to Channel 1 positive red terminal of amp repeat for negative Repeat Channel 2 wiring as for Channel 1 To wire stereo speakers to the Speakon connectors use one of these methods Method 1 Wire one Sp...

Страница 6: ...tion 3 IMPORTANT Turn off the amplifier and unplug its power cord INPUTS There are three ways to connect an input signal to the amplifier Connect an analog signal source to the Channel 1 amplifier inp...

Страница 7: ...timum gain structure sig nal levels please refer to the Crown Amplifier Application Guide available online at www crownaudio com Precautions Your amplifier is protected from internal and external faul...

Страница 8: ...g Blackout mode 10 dB Indicator amplifier output is 10 dB below clipping 20 dB Indicator amplifier output is 20 dB below clipping Signal Indicator selected input signal is abouve 40 dBu Ready Indicato...

Страница 9: ...t Status Cobranet Source Select Cobranet Input Trim Bandpass Gain Output Polarity Input Delay Speaker Delay LED Meter Display Type Bar Meter Display Type LevelMax Peak Voltage Limiter RMS Voltage Limi...

Страница 10: ...preset will automat ically set the DSP parameters as you set them up in the control software Setting some parameters of the DSP in the I Tech HD amplifier is done using the control software not by th...

Страница 11: ...96kHz converters offer extremely low noise and extended dynamic range When you use an I Tech HD amp the loud speaker processors crossovers limiters and delays are in the onboard DSP so you don t need...

Страница 12: ...POSSIBLE REASON The amplifier is becoming too hot for safe operation Allow amplifier to cool Check for loads less than 2 ohms and for excessive input levels Check for proper ventilation CONDITION Faul...

Страница 13: ...from the affected channel s one by one to determine if one of the loads is shorted CONDITION Data indicator not flash ing even though host computer software is active POSSIBLE REASON Cable between com...

Страница 14: ...floating point DSP processing 24 bit conversion with 32 bit floating point DSP processing Attenuators Speed sensitive rotary encoders 0 5 dB steps range 0 to 100 dB Speed sensitive rotary encoders 0 5...

Страница 15: ...eries Power Amplifiers I Tech HD Series Power Amplifiers page 28 page 29 Operation Manual Operation Manual Charts Typical Frequency Response 1W Typical Crosstalk vs Frequency Typical Damping Factor vs...

Страница 16: ...1625 376 1040 262 7 8 4 4 6 0 9 5 9 4 58 1 77 1 77 0 70 3 106 9 96 1 126 2 129 1 106 0 139 9 Watts Dissipated 120VAC 208VAC 230VAC 102 6 AC Power Draw and thermal Dissipation I Tech 9000HD AC Current...

Страница 17: ...engage the input compressor and the clip LED will illuminate By compress ing the input the amplifier will not generate as much heat and will have a chance to cool down The degree of compression is pr...

Страница 18: ...event electric shock do not remove covers No user serviceable parts inside Refer servicing to a qualified technician Complete the Crown Audio Factory Service Information form in the back of this manua...

Страница 19: ...unit in a wood or metal cabinet 4 If you provide your own shipping pack the mini mum recommended requirements for materials are as follows a 275 P S I burst test Double Wall carton that allows for 2 i...

Страница 20: ...om time to time without notice and with no obligation to make corresponding changes in products previously manufactured LEGAL REMEDIES OF PURCHASER THIS CROWN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS...

Страница 21: ......

Отзывы: