CONDITION: No sound, even though 

the amp has power. 

Power LED is on with-

out flashing and the amp is receiving an input 

sig nal. Signal indicator is on or flashing.

POSSIBLE REASON

•  Speakers not connected.
•  Open circuit due to speaker failure.

•  Ready LED is off. Channel has been set to 

standby mode via the software.

•  Amplifier is in blackout mode. Press or 

turn an Encoder to reactivate the LCD 

display.

CONDITION: No input signal. 

Signal 

indicator is not flashing even though audio is 

applied, and the channel is ready.

POSSIBLE REASON

•  Input signal level is very low.
•  Another source is selected or routed.

•  There is a short on the amplifier output. First 

disconnect your speakers from the affected 

channel(s) one by one to determine if one of 

the loads is shorted.

CONDITION: Data indicator not flash­

ing, even though host computer 

software is active.

POSSIBLE REASON:

•  Cable between computer and amplifier is bro ken 

or not connected.

Note: Data indicator flashes only when the amplifier 

is polled for data, or is polled to see whether it is 

online.

CONDITION: Yellow LINK ACTIVITY indicator in 

Ethernet connector does not illuminate or flash.

POSSIBLE REASON:

•  Ethernet link is broken.

CONDITION: Computer does not communicate with the 

network devices.

POSSIBLE REASON:

•  Incorrect wiring. See Section 3.5 letter O on network wiring.
•  IP Addressing is not done correctly. Use the Network Troubleshooting 

Wizard in System Architect.

CONDITION: COND indicator is off.

POSSIBLE REASON:

• There is only one conductor allowed per network system. This 

indicator is lit only when the amplifier is the conductor.

•  Amplifier is in blackout mode. Press or turn an Encoder to 

reactivate the LCD display.

Содержание I-T9000 HD

Страница 1: ...s of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www crownaudio com Trademark Notice Crown...

Страница 2: ...e harmfulinterference and 2 thisdevicemustacceptanyinterference received including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the party...

Страница 3: ...d switching power supply 15 Thermal management controller and two dis crete thermal zones with variable speed fans forced air cooling 16 Advanced protection circuitry guards against shorted outputs DC...

Страница 4: ...bel If you are unsure of the output voltage of your AC mains please consult your electrician Packed with your I Tech amplifier is a clip that retains the power cord so it can t pull out accidentally 1...

Страница 5: ...d to Channel 1 positive red terminal of amp repeat for negative Repeat Channel 2 wiring as for Channel 1 To wire stereo speakers to the Speakon connectors use one of these methods Method 1 Wire one Sp...

Страница 6: ...tion 3 IMPORTANT Turn off the amplifier and unplug its power cord INPUTS There are three ways to connect an input signal to the amplifier Connect an analog signal source to the Channel 1 amplifier inp...

Страница 7: ...timum gain structure sig nal levels please refer to the Crown Amplifier Application Guide available online at www crownaudio com Precautions Your amplifier is protected from internal and external faul...

Страница 8: ...g Blackout mode 10 dB Indicator amplifier output is 10 dB below clipping 20 dB Indicator amplifier output is 20 dB below clipping Signal Indicator selected input signal is abouve 40 dBu Ready Indicato...

Страница 9: ...t Status Cobranet Source Select Cobranet Input Trim Bandpass Gain Output Polarity Input Delay Speaker Delay LED Meter Display Type Bar Meter Display Type LevelMax Peak Voltage Limiter RMS Voltage Limi...

Страница 10: ...preset will automat ically set the DSP parameters as you set them up in the control software Setting some parameters of the DSP in the I Tech HD amplifier is done using the control software not by th...

Страница 11: ...96kHz converters offer extremely low noise and extended dynamic range When you use an I Tech HD amp the loud speaker processors crossovers limiters and delays are in the onboard DSP so you don t need...

Страница 12: ...POSSIBLE REASON The amplifier is becoming too hot for safe operation Allow amplifier to cool Check for loads less than 2 ohms and for excessive input levels Check for proper ventilation CONDITION Faul...

Страница 13: ...from the affected channel s one by one to determine if one of the loads is shorted CONDITION Data indicator not flash ing even though host computer software is active POSSIBLE REASON Cable between com...

Страница 14: ...floating point DSP processing 24 bit conversion with 32 bit floating point DSP processing Attenuators Speed sensitive rotary encoders 0 5 dB steps range 0 to 100 dB Speed sensitive rotary encoders 0 5...

Страница 15: ...eries Power Amplifiers I Tech HD Series Power Amplifiers page 28 page 29 Operation Manual Operation Manual Charts Typical Frequency Response 1W Typical Crosstalk vs Frequency Typical Damping Factor vs...

Страница 16: ...1625 376 1040 262 7 8 4 4 6 0 9 5 9 4 58 1 77 1 77 0 70 3 106 9 96 1 126 2 129 1 106 0 139 9 Watts Dissipated 120VAC 208VAC 230VAC 102 6 AC Power Draw and thermal Dissipation I Tech 9000HD AC Current...

Страница 17: ...engage the input compressor and the clip LED will illuminate By compress ing the input the amplifier will not generate as much heat and will have a chance to cool down The degree of compression is pr...

Страница 18: ...event electric shock do not remove covers No user serviceable parts inside Refer servicing to a qualified technician Complete the Crown Audio Factory Service Information form in the back of this manua...

Страница 19: ...unit in a wood or metal cabinet 4 If you provide your own shipping pack the mini mum recommended requirements for materials are as follows a 275 P S I burst test Double Wall carton that allows for 2 i...

Страница 20: ...om time to time without notice and with no obligation to make corresponding changes in products previously manufactured LEGAL REMEDIES OF PURCHASER THIS CROWN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS...

Страница 21: ......

Отзывы: