INSTALLATION AND OPERATION MANUAL, DIRECT STEAM KETTLES MOUNTED ON GAS
BOILER CABINET BASE, GMT-6, GMT-10, GMT-6-6, GMT-10-6, GMT-10-10
PART NUMBER 10072R1
25
2005-09-21
7.0 TROUBLESHOOTING
(Continued)
10.
Unit in 100% lock out. Turn off and try again in five minutes.
11.
Cracked ceramic insulator on pilot/ignitor sensor. Replace.
12.
No spark, ignition module malfunction. Replace.
13.
Pilot not adjusted correctly.
BURNER DOES NOT COME ON
1. Gas supply to unit is “OFF”.
2. Manual shut off valve is “OFF”.
3. Power supply is “OFF”.
4. Faulty valve or ignition module.
5. Pilot out.
6. Pilot may require flame adjustment.
7. Water level has not been reached in boiler. Check water supply is on, check water level
control.
8. If water at proper level, check relay which energizes pressure switch and gas control.
9. Pressure switch may need to be replaced if relay is operating.
10.
Gas control may also require replacement if energized but not operating.
11.
High Limit Thermostat open.
SAFETY RELIEF VALVE BLOWS
1. Defective valve.
2. Pressure too high, pressure switch requires adjustment (lower) or may be defective.