7.0 TROUBLESHOOTING
CAUTION: The appliance and its parts are hot. Use care when
operating, cleaning and servicing the appliance.
BURNERS PRODUCE CARBON DEPOSITS
1. Wrong size orifices.
2. Burner air not adjusted properly.
3. Wrong gas supply.
4. Incorrect pressure at supply.
PILOT DOES NOT LIGHT OR GOES OUT
1. Gas not on.
2. Power supply is off.
3. Gas control knob is off.
4. Low incoming gas pressure.
5. Check thermocouple millivolts.
6. Dirty or loose wire connection to ignition module. Clean and/or tighten.
7. Pilot outage due to draft, excess steam from drain or unit not level. Improper venting can
direct the flame away from the thermocouple or flame sensor.
8. Ignitor cable shorting out. Check that it is not contacting with metal or isn’t damaged. May
require replacement.
9. Ignition module not receiving power. Check output voltage from transformer is 24 volts.