5.2 Digital Multimeter Parameters
The following procedures are general in nature; for in-depth service, and repair see
the Service & Support section of this manual.
Lethal voltages present!
Only technically qualified
individuals shoud attempt
troubleshooting or service
procedures
.
If any abnormal readings are displayed for any of the following parameters on the
Digital Multimeter, try troubleshooting in the following manner:
5.2.1 In Ref (Input Drive Reference)
If this indication of drive level is not between 0.4 and 0.8 volts, then:
q
Check the exciter to ensure proper power input level of 25–30 watts.
q
Check RF input cable for secure connection.
5.2.2 SWR (Standing Wave Ratio)
If the SWR is over 1.5:1, then look for:
q
effects of inclement weather such as icing on the antenna and feed line.
q
for moisture in the feedline.
q
insecure antenna connections.
5.2.3 ALC (Automatic Level Control)
If this indication is not between 4.00 and 6.00 volts for 1.1 kW output, then:
q
Check for overheating (see PA Temp fault LED).
q
Check for overcurrent (see PA DC fault LED).
q
Check for high SWR (see Antenna fault LED).
5.2.4 Power Out
This reading is user adjustable, but for full output should read 1.10 for 1.1 kW.
q
If lower than desired, check for proper input drive, and/or proper adjustment
of the Local Power Control (see section 3.1 #6).
Содержание FM1000A
Страница 44: ...6 8 FM1000A User s Manual Illustration 6 5 PA1000 Block Diagram...
Страница 47: ...6 11 Reference Drawings RF Output Combiner...
Страница 49: ...6 13 Reference Drawings Backplane Distribution Note All bypass capacitors are 0 01 mf...
Страница 50: ...6 14 FM1000A User s Manual Ribbon Cables and Connectors Ribbon Cables and Connectors...
Страница 52: ...6 16 FM1000A User s Manual Notes...
Страница 56: ...7 4 FM1000A User s Manual Notes...