3–5
Operation
3.2.2 DC Power Switch
The main on/off power switch located on the front panel of the power supply
controls high voltage output. (The control circuit activates this voltage.)
Illustration 3–5 DC Power Switch
Illustration 3–6 Interlock Switch
Interlock Switch
®
Power
I
O
Power Switch
W
WARNING
ARNING
Lethal voltages are still present on the AC Input Board !
So, handle with care.
3.2.3 Interlock Switch
This switch is located on the fan mounting bracket in the power supply. When the
top cover of the power supply is removed, the Interlock Switch interrupts the
power supply control circuit disabling the high and low voltage supplies.
Содержание FM1000A
Страница 44: ...6 8 FM1000A User s Manual Illustration 6 5 PA1000 Block Diagram...
Страница 47: ...6 11 Reference Drawings RF Output Combiner...
Страница 49: ...6 13 Reference Drawings Backplane Distribution Note All bypass capacitors are 0 01 mf...
Страница 50: ...6 14 FM1000A User s Manual Ribbon Cables and Connectors Ribbon Cables and Connectors...
Страница 52: ...6 16 FM1000A User s Manual Notes...
Страница 56: ...7 4 FM1000A User s Manual Notes...