If the furnace fails to heat up:
•
Check fire.
•
Check fan for operation.
•
Check that solenoid damper is open to allow air velocity.
•
Check water level of furnace.
•
Check for creosote blockage at chimney and bypass trough.
•
Check temperature setting.
•
Check for power at furnace.
If furnace water is hot, but buildings do not have heat:
•
Check pumps and check for closed valves.
•
Check filter or Y-Strainer for flow blockage.
•
Check for air in system at exchanger by bleeding off.
If furnace boils:
•
Check that door is closing properly and that door gasket is completely sealed.
•
Check that the ash pan door is properly closed and the gasket is completely sealed.
•
Check that the solenoid damper plate is opening and closing without hang-ups.
•
Check that the flexible air duct is connected to the blower and the bottom elbow of the furnace.
•
Check that the temperature settings are correct and water levels.
If furnace has shut down:
•
Check to ensure that the unit has power (does the outside light work).
•
Check the water temperature (furnace has a high temperature cut-out of 190 degrees F.).
•
If all the checks have not corrected the problem have a qualified technician check the control panel.
Blower will not come on:
•
Check to see if the high limit switches may be shut off because of water temperature is higher than aqua stat setting.
•
Wait and allow water to cool down. Reset snap disc.
TROUBLESHOOTING
29
Содержание RS7300MP
Страница 2: ......
Страница 4: ......
Страница 6: ...6...
Страница 8: ...8...
Страница 11: ...CONCRETE PAD DIMENSIONS 7300MP 7400MP A 49 56 B 62 73 C 13 5 15 D 13 5 15 E 6 5 6 25 F 6 5 6 25 11...
Страница 18: ...18...
Страница 22: ...22...
Страница 30: ...30...
Страница 32: ...32...
Страница 38: ...38...
Страница 44: ...44...
Страница 47: ...Please mark the affected area of the stove on the diagram below 47...
Страница 48: ...48...
Страница 57: ......
Страница 58: ...OWNER S MANUAL...