24
CONTROL PANEL
P: 866-361-7355
F: 218-283-5786
W: www.crownroyalstoves.com
Greentech Manufacturing, Inc. 2716 Crescent Dr International Falls MN 56649
FAN/LIGHT SWITCH
AQUA STAT
Controls the water
temperture inside the
water jacket. Factory set
at 160°F with a 10° differential.
Controls both fan and light.
Ensure switch is in the light
position before opening
fuel door. This shuts the
fan off and turns on light.
Always put the switch in
the fan position after
refueling.
The control panel door is to be shut when fueling the firebox and at all other times except when using the controls.
The aqua stat powers the inducer draft blower to maintain the desired water temperature. The aqua stat is set at 160°F at the factory, which means the
inducer will run until the water in the jacket reaches 160°F. As the outside air temperature drops as the season progresses into the winter the settings
can be raised to a high of 180°F. The reason the aqua stat is set lower is that it is not necessary to have a high temperature in the fall and spring.
Therefore, the stand by heat loss is reduced. Only qualifed personal should be adjusting the temperature controls.
The on and off switch is to shut the power off to the inducer blower when the firebox is being filled. The outside light is wired so it can be turned on and
off at a remote location.