4
READ THIS ENTIRE MANUAL
before attempting
installation, start-up, or service. Improper
installation, adjustment, alteration, service, or
maintenance may cause serious property damage,
personal injury, or death.
DO NOT DISCONNECT PIPE FITTINGS on the boiler
or in the heating system without first verifying that
the system is cool and free of pressure and that
your clothing will protect you from a release of hot
water or steam. Do not rely solely on the boiler’s
temperature and pressure gauge when making this
judgment.
USE PROPER PERSONAL PROTECTION
EQUIPMENT
when servicing or working near the
boiler. Materials of construction, flue products, and
fuel contain alumina, silica, heavy metals, carbon
monoxide, nitrogen oxides, and/or other toxic or
harmful substances that can are hazardous to
health and life and that are known to the State of
California to cause cancer, birth defects, and other
reproductive harm.
INSTALL ALL GUARDS, cover plates, and
enclosures before operating the boiler.
SIZE THE BOILER PROPERLY
relative to the design
heat load or, if using domestic hot water priority,
the peak hot water load, whichever is larger. A
grossly oversized boiler will cycle excessively and
this will lead to premature failure of the boiler and
its components. Our warranty does not apply to
damage from excessive cycling.
ADHERE TO ALL LOCAL CODE REQUIREMENTS.
Contact your local code inspector prior to
installation. In the absence of a local code, adhere to
the latest editions of the
Installation of Oil Burning
Equipment ANSI/NFPA 31
in the USA or
CAN/CSA
B139, Installation Code for Oil Burning Equipment
in
Canada.
ALL WIRING must comply with the
National
Electrical Code ANSI/NFPA 70
(in the USA) or the
Canadian Electrical Code CSA C22.1
(in Canada)
and any local regulations.
WARNINGS FOR THE INSTALLER
WARNING
This boiler must be properly vented. The chimney must be inspected for any obstructions and cleaned
prior to each heating season. A clean and unobstructed chimney flue is necessary to produce the minimum
draft required to safely evacuate noxious fumes that could cause personal injury or loss of life. Evidence
of loose debris and or condensate induced stains at the base of the chimney flue, connector or smokepipe
joints may be signs of condensing flue gases. Flue gas condensate is corrosive, which requires special
consideration and must be addressed immediately. Refer to Section VII, "Venting" in this manual for
more details.
This boiler needs fresh air for safe operation and must be installed so there are provisions for adequate
combustion and ventilation air.
This boiler is supplied with controls which may cause the boiler to shut down and not re-start without
service. If damage due to frozen pipes is a possibility, the heating system should not be left unattended in
cold weather; or appropriate safeguards and alarms should be installed on the heating system to prevent
damage if the boiler is inoperative.
This boiler is designed to burn No. 2 fuel oil only. Do not use gasoline, crankcase drainings, or any oil
containing gasoline. Never burn garbage or paper in this boiler. Do not convert to any solid fuel (i.e.
wood, coal). Do not convert to any gaseous fuel (i.e. natural gas, LP).
All boilers equipped with burner swing door have a potential hazard which, if ignored, can cause severe
property damage, personal injury or loss of life. Before opening swing door, unplug burner power cord
from receptacle located in lower right corner of jacket front panel and turn off service switch to boiler
to prevent accidental firing of burner outside the combustion chamber. Be sure to tighten swing door
fasteners completely when service is completed.
Содержание TWB Series
Страница 2: ......
Страница 12: ...10 FIGURE 4 1 FIELD INSTALLATION OF FLUE BAFFLES...
Страница 18: ...16 FIGURE 6 4 ALLAIR FROM OUTDOORS USING HORIZONTAL DUCTS INTO BOILER ROOM...
Страница 23: ...21 FIGURE 8 3 BOILER BYPASS PIPING FIGURE 8 2 INDIRECT WATER HEATER BOILER SIDE PIPING...
Страница 31: ...29 FIGURE 11 0 CONNECTIONS DIAGRAM BOILERS WITH OR LESS TANKLESS HEATER...
Страница 32: ...30 FIGURE 11 1 CONNECTIONS DIAGRAM FOR BURNER PRIMARY CONTROLS Carlin 40200 Beckett 7505 Riello 530SE...
Страница 51: ...49...
Страница 53: ...51...
Страница 54: ...52 SERVICE RECORD DATE SERVICE PERFORMED...
Страница 55: ...53 Notes...