Installation
16
English
Armoured cable
1. Backnut
2.
Compression Spigot
3.
Compression seal
4.
Middle Nut
5.
Reversible Armour Clamping Ring
6.
Armour Spigot
7.
Inner seal
8. Entry
1.
Expose the armour/braid “A” by
stripping the cable's armoured / woven
layer and removing the cable fi ller.
2.
Push the cable through the Armour
Spigot. Spread armour/braid over the
Armour Spigot until the end of the
armour/braid is up against the shoulder
of the armour cone. Position the
Armour Clamping Ring.
3.
Remove the Inner seal from the Entry.
Place the Entry over the Armour Spigot.
Move the Middle Nut to meet the Entry.
4.
Hold the Entry in position with a
spanner/wrench to prevent rotation.
Hand tighten the middle Nut to the
Entry and turn a further half to one
full turn with a spanner/wrench.
5.
Unscrew the Middle Nut and visually
inspect that the armour/braid has been
successfully clamped between the
Armour Spigot and the Armour
A=15mm
Содержание Xgard Bright