background image

Important:

Assembly  /  maintenance  of  the  appliance  must  be  carried  out  by  qualified  personnel  and  in  accordance  with
applicable  laws  and  regulations.
The  manufacturer  assumes  no  responsibility  for  the  use  of  products  that  have  to  comply  with  particular
environmental  and  /  or  installation  standards.

Important note

Before  connecting  the  equipment,  it  is  recommended  that  you  read  the  instruction  manual  carefully  and  keep
it  for  future  reference.  It  is  also  recommended  to  perform  the  electrical  connections  correctly  as  per  enclosed
drawings,  observing  the  instructions  and  the  Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side

Stand-alone Gas Sensor SG850

                                                          V. R4

Instrument of testing TS1008
To facilitate the reading of the functional parameters of the probe as well as the
control of annual operating, the BEINAT  S.r.l.  has built a new portable tester TS1008.
The tester allows to read all the data in the memory of the probes eand by serial
transmission, it prints the ticket that confirms the testing data, certifying your own work.

The SG850 is born from the elegance and prestige that has always distinguished  BEINAT  S.r.l. and from the home
fitness  concept.
The device is a IP66 gas detection unit that, either combined with a BEINAT industrial control unit or in stand alone
mode, detects the presence of:
- Oxygen
- Carbon Dioxide

SG850-O

FOR OXYGEN DETECTION

This sensor, through an optical fluorescence technology based sensor, detects the presence of: Oxygen (O

2

)

With this probe it is possible to:
1) S

ELECT

 

THE

 A

LARM

 

INTERVENTION

 

FOR

:  > O

XYGEN

 E

XCESS

  

OR

  <D

EFICIENCY

2) S

ELECT

 

THE

 

POSITIVE

 

SAFETY

 

OF

 

THE

 

RELAY

SG850-CO

FOR CARBON DIOXIDE DETECTION

This sensor, through an infrared technology based sensor, detects the presence of: Carbon dioxide (CO

2

)

With this probe it is possible to:
1) S

ELECT

 A

LARM

 

THRESHOLDS

: 5%, 10%, 15% 

OR

 20%

2) S

ELECT

 

THE

 

POSITIVE

 

SAFETY

 

OF

 

THE

 

RELAY

The probe is managed by a microprocessor which not only supplies an alarm signal to the control unit connected to
the device, but also maneges the execution of a self-diagnosis, and related AUTOMATIC CALIBRATION,

 

in order to always

have the maximum detection accuracy.
With this self-calibration the probe adapts its detection in harsh and variable temperature environments, avoiding false
alarms due to anomalous events.
The sensor, based on its range of detection, has a linear output conforming to the 4 ÷ 20mA standard, for which can
be connected with one of BEINAT's industrial control units.

Install in a safe  area

No ATEX

Installation and

user guide

Channel:  Beinat  gas  solutions

CONFORMITY

Electric connections also available on

EN 50270

EN 61010-1

Compliant  EN 60079-29-1

Installation  EN 60079-29-2

Reports issued by  TUV Italia

    Belonging   to

Содержание SG850

Страница 1: ...AT industrial control unit or in stand alone mode detects the presence of Oxygen Carbon Dioxide SG850 O2 FOROXYGEN DETECTION This sensor through an optical fluorescence technology based sensor detects the presence of Oxygen O2 With this probe it is possible to 1 SELECT THE ALARM INTERVENTION FOR OXYGEN EXCESS OR DEFICIENCY 2 SELECT THE POSITIVE SAFETY OF THE RELAY SG850 CO2 FOR CARBON DIOXIDE DETE...

Страница 2: ... 100x100x60 CHECK the integrity of the unit after having removed it from the box Check that the data written on the box correspond to the type of gas used When doing the electrical connections follow the drawing closely Any use of the detector for purposes other than the intended one is considered improper and as a result of which BEINAT S r l therefore disclaims any responsibility for possible da...

Страница 3: ...dition is reached At least once a year make a more accurate check by a specialist technician Disabling the detector must be carried out by qualified personnel Side view 60 mm Compatible control units Only Oxygen CONTROL UNITS MOUNTING PROBES Max DEGREE PRE ALARMS POSITIVE OPERATING protec alarms safety range GS300 Mc unit 1 zone Wall cabinet 3 IP44 2 1 YES NO BX444 MC unit 1 zone Wall cabinet 4 IP...

Страница 4: ...oor Light medium gas volatile The probe should not be placed near the appliances to be controlled boilers burners industrial kitchens etc but on the opposite wall The probe should not be affected by smoke vapour etc as they could distort their measurement It must be placed away from sources of heat suction fans ventilation fans Page 4 0 18 5 19 5 20 9 22 5 23 5 25 0 vol 0 4 15 8 16 5 17 4 18 4 19 ...

Страница 5: ...age at the terminals 1 2 It must be higher than 11Vdc and lesser than 25Vdc Check the voltage at the terminals 2 3 It must be from a minimum of 0 8 Vdc to a maximum of 1 1 Vdc If other problems arise the Distributor of BEINAT S r l should be contacted directly Linear Otput 4 20 mA 3 2 1 R 0 1 3 2 1 1 VDC Voltmeter Power Supply 12 24 V WARNING These measurement should be performed in clean air More...

Страница 6: ... Fault Operating LEDs IMPOSTAZIONI ALLARMI MICRO INTERRUTTORI n 2 n 3 5 OFF OFF 10 OFF ON 15 ON OFF 20 ON ON SWITCH 1 Positive safety Position ON Positive security enabled Position OFF Positive security disable WARNING Before connecting to the mains power ensure the voltage is correct Carefully follow the instructions and the connections according to Regulations in force keeping in mind that the s...

Страница 7: ...nder tap 3 Do not turn any lights on or off do not turn on any electrical device or appliance 4 Open windows and doors in order to increase ventilation If the alarm stops its cause must be found and the relevant consequent measures taken If the alarm continues and the cause of gas presence cannot be found or removed abandon the building and call the emergency services when outside fire department ...

Страница 8: ...ts in case you buy a new and similar product local collection points waste collection center local recycling center etc By ensuring this product is disposed of correctly you will help prevent potential negative consequence for the environment and human health which could otherwise be caused by inappropriate waste handing of this product The recycling of materials will help to conserve natural reso...

Отзывы: