Page 3
The installation of the detector is not exempt from ...… The compliance with all regulations concerning the characteristics,
installation and use of gas appliances. The ventilation of the spaces and the elimination of combustion products are described
in the UNI norms according to ART. 3 LAW 1083 / 71 and relevant legal provisions.
MAINTENANCE
The user periodically (every 6 months) must perform a check of the operation of the control unit
by spraying a suitable test gas at the base of the probes connected until the alarm condition
is reached.
• At least once a year make a more accurate check by a specialist technician.
• Disabling the detector must be carried out by qualified personnel.
Side view
60 mm
Compatible control units Only Oxygen
CONTROL UNITS
MOUNTING
PROBES Max. DEGREE PRE
ALARMS POSITIVE OPERATING
protec. alarms
safety range
GS300-Mc unit 1 zone
Wall/cabinet
3
IP44
2
1
YES
N O
BX444-MC unit 1 zone
Wall/cabinet
4
IP44
2
1
YES
N O
BX449F unit 1 zone
Omega bar DIN
4
IP20
1
1
YES
N O
BX308 unit 1 zone
Omega bar DIN
8
IP20
1
1
YES
yES
BX308/Box unit 1 zone
Wall
8
IP65
1
1
YES
YES
BX316 unit 2 zones
Barra Omega
16
IP20
1
2
YES
YES
BX316/Box unit 2 zones
Wall
16
IP65
1
2
YES
YES
80 mm
8
0
mm
Rear View
Hole 6,5 mm
100 mm
1
0
0
mm
4
0
mm
Front View