O�eration
Gas-Tec
12
Attach the shoulder strap (below) .
Attach both ends of the strap to the metal rods at either end of the Gas-Tec .
Using headphones:
Plug the headphones into the headphone jack at the base of the Gas-Tec . This will silence external
alarms and notifications of gas detection, leaving only the user to hear the increasing tones .
3.2 Start Up
When the hydrogen cylinder and the probe are
properly attached, the Gas-Tec can be switched
on .
1 . Press the ON/OFF button .
The LCD display will run a self test and then
be ready for use .
2 . Press START .
3 . The LCD display will show the message ‘Turn on the gas
supply’ (if the cylinder is not already turned on) .
4 . To open up the gas supply, turn the gas cylinder ON/OFF
valve on the side of the hydrogen bottle
anticlockwise
. Turn
until there is no more resistance .
5 . Providing the gas supply is adequate, the pump will start .