background image

 

10 

 

11 

 

12 

FIG. 3 - TLC-360 BOTTOM VIEW 

 

IMPORTANT: 

1.  Do not install the detector where it may 

encounter water, steam or oil. 

2.  Do not aim the detector directly at 

sources of rapid heating or cooling such 
as: forced air ducts, heaters. 

3.  Be sure to locate the detector so that 

valuables are well within its coverage 
pattern. 

4.  Range may vary in accordance with 

ambient temperature. 

 

DETECTION PATTERN FOR TLC-360 

Installation  Height

Detection

 Diameter

(Effective

Range)

2.4m

8 ft

11m

36  ft

3m

10ft

14m

46ft

3.6m

12ft

16m

52ft

 

Example: 

(See Fig. 4). If installed at a 

height of 3 m (10 ft), the detector will cover a 
circle of 20m (65.5 ft) at floor level, with an 
effective detection range of 14m (45.9 ft) in 
diameter. 

Note:

 The detection range is the circle 

pattern at floor level. The effective range is 
the range at which an intruder will trigger an 
alarm. 

  WALK TEST 

After the installation, perform a walk test to 
check that the detector operates properly. 
  
 

 

 

FIG. 4 - TLC-360 DETECTION AREA 

 
 

13 

 

14 

 

15 

DIP-SWITCH SETTINGS 

PULSE COUNT

 - DIP-SWITCH, “PULSE” - 

provides control for normal or high risk 
operating environments.

 

Position “1”

 (ON) - this setting is for a 

stable environment. 

Position “Auto”

 (OFF) - the TLC-360 will 

automatically select the appropriate pulse 
count level (2 or 3) according to the strength 
of the incoming signals. This setting is for 
operation within a harsh environment.

 

 

When an intrusion is detected, the LED will 

activate and the alarm relay will switch into 
alarm condition (open circuit) for 1.6 sec. 

 LED ENABLE - 

DIP-SWITCH, “LED” - 

to enable or disable the LED. 

Position “ON”

 - LED enable. 

Position “OFF”

 - LED disable.

 

 

FIG. 5 - LENS PATTERN 

 

 

 

TECHNICAL SPECIFICATIONS 

 

Power Input 

8.2 - 16 Vdc 

Current Draw 

Active / Standby: 9 mA 

Detection Method 

4 (Four) element PIR 

Sensitivity 

2

°

C (

3.6

°

F) at  

 

0.6 m/sec (2 ft/sec)  

Detection Speed 

0.5 - 1.5 m/sec  

 

(1.5 - 5 ft/sec) 

Bi Directional 
Temperature 

YES 

Pulse Count 

1,2-automatic switch from 

 

2 to 3 depending on  

Alarm Period 

1.6 sec 

Alarm Output 

N.C 28VDC 0.1 A 

 

 with 10 Ohm series        

 

protection resistor 

Tamper Switch 

N.C 28VDC 0.1A with  

 

10 Ohm series protection 

 

resistor - open when 

 

cover is removed 

 

16 

 

17 

 

18 

TECHNICAL SPECIFICATIONS (CONT.) 

 

Warm Up Period 

20 sec 

LED Indicator 

LED is blinking 

 

during warm up period 

 

and self testing, LED is 

 

ON during alarm 

Operating Temperature  -20

°

C to+50

°

C

            

 

(-4

°

F to +122

°

F)

 

RFI Protection 

 30V/m             

 

10 - 1000MHz 

EMI Protection 

50,000V of 

 

electrical 

 

interference from 

 

lightning or power 

 

through 

Visible Light Protection  stable against 
 

halogen light 2.4m  

 

(8 ft) or reflected 

 

light 

Dimensions 

 110mm x 45mm 

 

 (

 4.33” x 1.77”) 

Weight 

123 gr. ( 4.37 oz )

 

 

 

 

SECURITY MERCHANTS AUSTRALIA P/L (SMA) 

 WARRANTY POLICY CERTIFICATE 

This  Warranty  Certificate is given in favor of the purchaser (hereunder the "

Purchaser

") purchasing the 

products directly from Security Merchants Australia P/L, herein referred to as SMA. 
SMA  warrants  these  products  to  be  free  from  defects  in materials and workmanship under normal use 
and service for a period of 24 months from the last day of the week and year whose numbers are printed 
on the printed circuit board inside these products (hereunder the "

Warranty Period

").

 

Subject  to  the  provisions of this Warranty Certificate, during the Warranty Period, SMA undertakes, at its 
sole discretion and subject to SMA’s procedures, as such procedures are from time to time, to repair or 
replace,  free  of  charge  for  materials  and/or  labor,  products  proved  to  be  defective  in  materials  or 
workmanship under normal use and service. Repaired products shall be warranted for the remainder of 
the original Warranty Period. 
All  transportation  costs  and  in-transit  risk  of  loss  or  damage  related,  directly  or  indirectly,  to  products 
returned to SMA for repair or replacement shall be borne solely by the Purchaser.  
SMA’s  warranty  under  this  Warranty  Certificate  does  not  cover  products  that  are  defective  (or  shall 
become defective) due to: (a) alteration of the products (or any part thereof) by anyone other than SMA; 
(b)  accident,  abuse,  negligence,  or  improper  maintenance;  (c)  failure caused by a product which SMA 
did not provide; (d) failure caused by software or hardware which SMA did not provide; (e) use or storage 
other than in accordance with SMA’s specified operating and storage instructions. 
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular 
purpose or otherwise, which extend beyond the description on the face hereof.  
This  limited  Warranty  Certificate  is the Purchaser's sole and exclusive remedy against SMA and SMA's 
sole and exclusive liability toward the Purchaser in connection with the products, including without limitation 
-  for  defects  or  malfunctions  of  the  products.  This  Warranty Certificate replaces all other warranties and 
liabilities, whether oral, written, (non-mandatory) statutory, contractual, in tort or otherwise. 
In no case shall SMA be liable to anyone for any consequential or incidental damages (inclusive of loss of 
profit, and whether occasioned by negligence of the SMA or any third party on its behalf) for breach of this 
or  any  other  warranty,  expressed  or  implied, or upon any other basis of liability whatsoever. SMA does 
not  represent  that  these  products  can  not  be  compromised  or  circumvented;  that  these  products  will 
prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that these 
products will in all cases provide adequate warning or protection.  
Purchaser understands that a properly installed and maintained product may in some cases reduce the 
risk of burglary, fire, robbery or other events occurring without providing an alarm, but it is not insurance 
or a guarantee that such will not occur or that there will be no personal injury or property loss or damage 
as a result.  
Consequently,  SMA  shall  have  no  liability  for  any  personal  injury;  property  damage  or  any  other  loss 
based on claim that these products failed to give any warning.  
If SMA is held liable, whether directly or indirectly, for any loss or damage with regards to these products, 
regardless of cause or origin, SMA’s maximum liability shall not in any case exceed the purchase price of 
these products, which shall be the complete and exclusive remedy against SMA.

 

 

 

Security Merchants Australia P/L 

VICTORIA 

Mount Waverley 

Unit 144, 45 Gilby Road Ph: (03) 9558 8455 Fax (03) 9558 8466 

Tullamarine 

Unit 7, 4-6 Commercial Court. Ph: (03) 9338 2427. Fax (03) 9338 1873 
 

NEW SOUTH WALES 

Northmead 

Unit 3, 1B Kleins Road. Ph: (02) 9890 5300. Fax (02) 9890 5600 

Alexandria 

Unit 33, 56 O’Riordan Street. Ph: (02) 9693 5966. Fax (02) 9693 5433 
 

QUEENSLAND 

Brisbane 

Unit 11, 81 Bishop Street. Ph: (07) 3552 5966. Fax: (07) 3552 5977 
 

SOUTH AUSTRALIA 

Marleston 

Unit 1, 60 Grove Ave. Ph: (08) 8297 5555. Fax: (08) 8297 5500 
 

WESTERN AUSTRALIA 

Balcatta 

Unit 5, 30 Erindale Road. Ph: (08) 9240 7500. Fax: (08) 9240 7511

 

 

 
 
 
 

 

 

      SMA Edit Quip TLC360 Manual.doc 

Ceiling 
3m (10ft) high 

14m (46ft) 

 

0.8m (2.6ft) 

 

Effective 

Detection 

Diameter 

Floor 

20m (65.5ft) 

 

0 (0)

 

3.6 (12)

 

3 (10)

 

2.4 (8)

 

TOP VIEW

 

SIDE VIEW

 

m (ft)

 

32.8 

 

21.6 

 

10.8

 

 0 

 

10.8

 

21.6

 

32.8

 

ft

 

10

 

6.6

 

3.3

 

0

 

3.3

 

6.6

 

10

 

m

 

20m (65.6ft)  

Отзывы: