SMI21 & SMI22 CANopen
C.MO.SAV.00019.FR_V2
Page 11/20
April 27th, 2018
3.3. Prior to Mounting
Look for any damage
Damaged drive systems must neither be mounted nor used.
Check the drive system prior to mounting, looking out for any visible signs of damage.
Clean the shaft
On leaving the factory, the motor shaft extensions are coated with a film of oil.
If transmission devices are to be glued on, it may be necessary to remove the film of oil and clean the shaft.
If necessary, use degreasing products in accordance with the glue manufacturer's instructions.
Avoid any direct contact between the skin or sealing materials and the cleaning product used.
Flange mounting surface
The mounting surface must be stable, flat and clean.
In regards to installation, make sure that all dimensions and tolerances are respected.
Specification of power supply leads
The power supply leads for the motor and its accessories must be selected carefully on the basis of their
length, the motor supply voltage, the ambient temperature, the current level circulating therein, and their
environment.
WARNING
DAMAGE AND FIRE DUE TO INCORRECT INSTALLATION
Repeated force and movement around the grommets can damage the
cables.
• Comply with the stated bend radius.
• Avoid subjecting the grommets to repeated force or movement.
• Attach the power supply cables close to the grommets using a strain
relief.
Failure to comply with these precautions can result in injury or
damage to equipment.