3.3. Prior to Mounting 

Look for any damage 

Damaged drive systems must neither be mounted nor used. 

  Check the drive system prior to mounting, looking out for any visible signs of damage. 

 
Clean the shaft  

On leaving the factory, the motor shaft extensions are coated with a film of oil. 
If transmission devices are to be glued on, it may be necessary to remove the film of oil and clean the shaft. 
If necessary, use degreasing products in accordance with the glue manufacturer's instructions. 

  Avoid any direct contact between the skin or sealing materials and the cleaning product used. 

 

Flange mounting surface 

The mounting surface must be stable, flat and clean. 

   In regards to installation, make sure that all dimensions and tolerances are respected. 

 
Specification of power supply leads  

The  power  supply  leads  for  the  motor  and  its  accessories  must  be  selected  carefully  on  the  basis  of  their 
length,  the  motor  supply  voltage,  the  ambient  temperature,  the  current  level  circulating  therein,  and  their 
environment. 

 

 

WARNING

 

 

DAMAGE AND FIRE DUE TO INCORRECT INSTALLATION 

Repeated force and movement around the grommets can damage the 
cables. 
• Comply with the stated bend radius. 
•  Avoid subjecting the grommets to repeated force or movement. 
• Attach the power supply cables close to the grommets using a strain 
relief.

 

Failure to comply with these precautions can result in injury or 
damage to equipment.

 

 

Содержание SMI21 80140301

Страница 1: ...his manual in a safe place Give this manual and any other documents relating to the product to anyone that uses the product Read and be sure to comply with all the safety instructions and the section...

Страница 2: ...3 Installation 8 3 1 Overview of the Installation Procedure 10 3 2 Electromagnetic Compatibility EMC 10 3 3 Prior to Mounting 11 3 4 Mounting the Motor 12 3 5 Electrical Installation 13 3 6 Connectin...

Страница 3: ...al safety instructions are identified by warning symbols Depending on how serious the situation is the safety instructions are split into 3 risk categories DANGER DANGER indicates a directly dangerous...

Страница 4: ...the mechanical electrical and electronic equipment in the whole installation 1 2 Use in Compliance with Industry Practice As demonstrated in these instructions this product is a component designed for...

Страница 5: ...tage on the power cable and check that it is less than 12 VDC Install protective covers and ensure they are closed before energization Failure to comply with these precautions will result in death or...

Страница 6: ...0 April 27th 2018 1 4 Standards and concepts The product is ROHS and REACH confirmed following European Directive 2011 65 CE Following this confirmation the product is CE marked The electrical design...

Страница 7: ...Never exceed the maximum axial and radial forces Protect the shaft from any impact When press fitting components do not exceed the maximum permissible axial force Failure to comply with these precaut...

Страница 8: ...ds These can cause sensitive equipment to fail Keep people with implants such as pacemakers away from the motor Do not place sensitive equipment in the immediate vicinity of the motor Failure to compl...

Страница 9: ...or is not designed to carry loads If subjected to stress the motor can be damaged or even fall Do not use the motor as a step Prevent the motor from being used in any way other than its intended purpo...

Страница 10: ...that the motor power supply leads must be kept separate from line supplies or cables carrying signals Comply with the following measures as concerns EMC Measures relating to EMC Effect Keep the cables...

Страница 11: ...cleaning product used Flange mounting surface The mounting surface must be stable flat and clean In regards to installation make sure that all dimensions and tolerances are respected Specification of...

Страница 12: ...rces leads to rapid bearing wear a broken shaft or damage to the internal encoder Never exceed the maximum axial and radial forces Protect the shaft from any impact When press fitting components do no...

Страница 13: ...tor itself or devices placed on the same power supply DANGER ELECTRIC SHOCK High voltages can appear unexpectedly on the motor connection The motor produces a voltage when the shaft turns Protect the...

Страница 14: ...erheating due to an electric arc Failure to comply with these precautions can result in injury or damage to equipment CAUTION IRREPARABLE PRODUCT DAMAGE CAUSED BY REVERSED POLARITY Incorrect connectio...

Страница 15: ...on Make sure this cannot cause any damage Do not continue with the test if there is anybody or any obstacle in the danger zone Failure to comply with these precautions can result in death serious inju...

Страница 16: ...he holding brake is fully released Make sure that the holding brake is fully released before initiating a movement WARNING UNEXPECTED MOVEMENT As a result of incorrect wiring or other error the drives...

Страница 17: ...for heat dissipation Check the temperature when performing a test Failure to comply with these precautions can result in injury or damage to equipment CAUTION VOLTAGE SURGES During braking phases the...

Страница 18: ...fixing Align the transmission device Balance the transmission device Contact the after sales service Check the rigidity of the motor fixing Axial vibration Transmission device incorrectly aligned Tra...

Страница 19: ...ind out what steps to take We recommend that the following operations are done at regular intervals Connections and fixing Check the connection cables and connections regularly for signs of damage Rep...

Страница 20: ...e holding torque indicated on the technical data sheet If the holding torque is markedly different from the stated values turn the motor shaft by hand 25 turns in both directions Repeat the operation...