2.5.5 Alarm Indications
An alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock.
ON POWER UP
NORMAL DISPLAY
PUSHING MENU/EXECUTE SEQUENCE
REV 1.00
U F=6850.000 G=+00
D F=4600.000 G=+20
SCROLL <>
SCROLL
PUSH BUTTON
REMOTE OFF
INT REF
UP MUTE OFF
SCROLL <>
SCROLL
PUSH BUTTON
SCROLL <>
SCROLL
PUSH BUTTON
SCROLL <>
SCROLL
PUSH BUTTON
PUSH BUTTON
Power Up
Normal Display
Menu 1 Up Frequency
Menu 2 Up Input Level (Set from
-40 to -10)
Menu 3 Up Gain (0 to +30)
Menu 4 Downconverter
Frequency in MHZ
Menu 5 Down Gain (set +30 to +50
for -15 to +5 dBm out level)
Menu 6 Up Mute
Menu 7 Set Unit to Remote
Operation
Menu 8 Select Internal or External,
10 MHz Ref (option - E)
Menu 9 Reference Offset
(option -O)
Menu 10 Set Remote Mode
(option -Q)
Menu 11 Set RS-485 Address
(option -Q)
Save? When “R” is selected in any
above menu or at the end
DN G = +30.0
SCROLL <>
SCROLL
PUSH BUTTON
UP INLVL = -20
UP G = +00.0
SCROLL <>
SCROLL
PUSH BUTTON
SCROLL <>
SCROLL
PUSH BUTTON
PUSH BUTTON
SAVE SETTINGS? Y N
SCROLL <>
PUSH BUTTON
R
R
R
R
R
R
R
RS 232
SCROLL <>
SCROLL
PUSH BUTTON
R
ADDRESS = 00
SCROLL <>
SCROLL
PUSH BUTTON
R
FREQ ADJUST
Offset = +0000
SCROLL <>
SCROLL
PUSH BUTTON
R
U F=6850.000
DN F = 4600.000
SCROLL <>
SCROLL
PUSH BUTTON
R
Figure 2.4 Menu Display and Sequence
2017-74 Manual, Rev. B
Page 18
10/27/10