2.5 Menu Settings
2.5.1 Functions
This section describes operation of the front panel controls. There are three operator switches, the LCD display
and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions
are (see Figure 2.4):
Power Up
Normal Display
Menu 1
Upconverter Frequency in MHz
Menu 2
Up Input Level (Set from -40 to -10)
Menu 3
Up Gain (0 to +30)
Menu 4
Downconverter Frequency in MHz
Menu 5
Down Gain (set +30 to +50 for -15 to +5 dBm out range)
Menu 6 Up
Mute
Menu 7
Set Unit to Remote Operation
Menu 8
Select Internal or External, 10 MHz Ref (option -E)
Menu 9
Frequency Reference Offset (option -O)
Menu 10
Set Remote mode (option -Q)
Menu 11
Set RS-485 address (option -Q)
Save Menu When “R” is selected in any above menu or after last menu.
Alarm indications appear on the LEDs (see figure 2.2).
All program changes must start with the operation of the Menu/Execute switch and must also end with the
operation of the Menu/Execute switch verified by the “
SAVE SETTINGS?
” Menu. If this sequence is not
followed, none of the changes will take effect. No program changes (except for gain adjustments) will be
evident until they are verified at the “
SAVE SETTINGS?
” Menu.
2017-74 Manual, Rev. B
Page 13
10/27/10