2.0.1 Connection to AC Input Power
The 4116-285-2450 is furnished with a pre-assembled AC power input cable as described below.
4116-2
4116-285-2450 Power Input Connector, FCI Clipper Series
Mating
Mating Connector FCI Clipper Series, CL1F1101, Crimp Pins
and C
CL101021
and CL101021 Backshell
Pin Input Connector Pin Description
1
100-240 ±10% VAC, 47-63 Hz, 20 watts max.
2
Neutral
3
Ground
2.1 Message Protocol
The serial format for the RS232/RS422/RS485 port is 9600 baud, 8 data bits, no parity, and 1 stop bit.
All messages consist of ASCII printable characters so standard terminals and terminal emulator programs may
be used to control and monitor the unit. All messages begin with the open bracket character “
{
”
(ASCII 0x7B)
and end with the close bracket character “
}
” (ASCII 0x7D). Messages consisting of commands to set or change
operating parameters and modes of the unit begin with “C” (ascii 0x43) followed by a command specific
character. Messages consisting of queries to report operating parameters and modes begin with “S”
(ASCII 0x53) followed by a parameter specific character.
2.2 M&C Commands
The following tables summarize the commands and status queries applicable to the
4116-285-2450 frequency converter.
*
PLEASE NOTE:
The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected.
4116-285-2450 Manual, Rev. 0
Page 6
02/11/21