background image

2.0  Installation

The 4116-21T23 Translator consists of a  

8” Wide X 6“ High X 16” Deep Weather Resistant* enclosure

A switching, ± 12, +24, +5 VDC power supply provides power for the internal assemblies. The 4116-21T23 
can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panel.  
See Drawing 2.2. for mounting dimensions.

Figure 2.0:  Model 4116-21T23 Translator

2.1 Connection to AC Input Power

The 4116-21T23 utilizes a pre-assembled AC power input cable as described below.

Table 2.0:  4116-21T23 AC Power Input Connector

4116-21

4116-21T23 Power Input Connector, FCI Clipper Series, CL1M1102 & Crimp Pins

Mating

Mating Connector Clipper Series, CL1F1101, Crimp Pins

and  C

CL101021 

and  CL101021  Backshell

Pin   Input  Connector  Pin  Description

1

 100-240 ±10% VAC, 47-63 Hz, 20 watts maximum

2

 Neutral

3

 Ground

2.2  Message Protocol

The serial format for the RS232/RS422/RS485 port is 9600 baud, 8 data bits, no parity, and 1 stop bit.  

All messages consist of ASCII printable characters so standard terminals and terminal emulator programs may 

be used to control and monitor the unit.  All messages begin with the open bracket character “

}

 

(ASCII 0x7B) 

and end with the close bracket character “

}

” (ASCII 0x7D).  Messages consisting of commands to set or change 

operating parameters and modes of the unit begin with “C” (ascii 0x43) followed by a command specific 

character.  Messages consisting of queries to report operating parameters and modes begin with “S” (ASCII 

0x53) followed by a parameter specific character.  

4116-21T23 Manual, Rev. B  

 

      Page 6

    

                     09/24/15  

Содержание 4116-21T23

Страница 1: ...cated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equip...

Страница 2: ...gainst defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies...

Страница 3: ...igned to be water resistant for installation in an outdoor enclosure antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be located out in...

Страница 4: ...sponse 50 dBc for two carriers at 4 MHz spacing each at 5 dBm out maximum gain Intermodulation 50 dBm spurious signal independent 1 0 2 19 and 2 31 3 0 GHz out max gain Spurious Out of Band 45 dB mini...

Страница 5: ...or MS3116F14 18P Contact Closure Alarms RS232 422 485 Ethernet Connector RJF21B Mating Cable Connector RJF6G Cable interface Standard RJ45 Web Browser SNMP User Interface Standard AC Input Connector C...

Страница 6: ...Crimp Pins and C CL101021 and CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts maximum 2 Neutral 3 Ground 2 2 Message Protocol The serial format for the RS232...

Страница 7: ...ternal reference where aaCEx Set 10 MHz reference mode Range 2000 to 2000 x 1 to select RS422 x 0 to unmute the output x 1 to mute the output where aaCMx Set Mute xxxxx 5 characters where aaCOxxxxx Se...

Страница 8: ...urns aaSRxx where aaSR RS485 address x 0 if RS232 is selected Returns aaSIx where aaSI Serial Interface x 2 if External 10 MHz reference is selected x 1 if Internal 10 MHz reference is selected Return...

Страница 9: ...internal 2 extenal w summary alarm 0 off 1 on returns aaSSwxyz where aaSS returns aaSVxxxxxxxxyyyy where aaSV Model and firmware revision Range 2000 to 2000 xxxxx 5 characters yyyy unit firmware rev x...

Страница 10: ...ernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4116 21T23 2 5 2 Ethernet Configuration Each 4116 21T23 must be configured with an appropriate IP address Netma...

Страница 11: ...ger click on Network to display the Network Settings screen Enter the IP address Subnet mask and Gateway address with delimiter dots example 192 168 192 47 Click apply settings in the left frame to ap...

Страница 12: ...port 9999 The following instructions explain how to establish such a Telnet connection using Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the...

Страница 13: ...NMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of S...

Страница 14: ...Figure 2 F Device Server Configuration Menu 4116 21T23 Manual Rev B Page 14 09 24 15...

Страница 15: ...arm RF OUT 60 to 0 dBm 2 20 2 30 GHz S Band Output ETHERNET CONNECTOR Weatherized Standard RJ45 Ethernet Connector RF INPUT Type N 50 2 02 2 12 GHz S Band Input RF IN MON Type N 50 10MHz INPUT SMA fem...

Страница 16: ...onitor and Control Connector Monito Monitor and Control Connector Pinout Conne Connector part number MS3112E14 18S Mating Mating Cable Connector part number MS3116F14 18P Pin Signal Description A Chas...

Страница 17: ...al 10 MHz 2 to 8 dBm reference that is inserted at J3 via Ethernet or serial command 8 Check that a 10 MHz signal is present at the 10 MHz REF OUTPUT at the same level as the input 0 5 dBm J4 See Draw...

Страница 18: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4116 21T23 Manual Rev...

Отзывы: