2.6 Outline Drawing: shows input and output connections on the front panel and top view of the 4116-
21T23.
RF OUT
J5
10M IN
ETHERNET
RF IN
J1
J2
POWER
ALARM
J3
J4
10M OUT
FUSE
J8
AC IN
J7
F1
C
ROSS
T
ECHNOLOGIES INC.
RF IN MON
MODEL 4116 TRANSLATOR
POWER IN
AC input 100-240 ±10% VAC
47-63 Hz. 25 watts max.
Weatherized CL 1M1102
Connector.
Fuse
1A 250V - 1.24” X .25”
slow blow
ALARM LED
Red LED indicates
unit alarm.
RF OUT
-60 to 0 dBm
2.20 - 2.30 GHz
S-Band Output
ETHERNET CONNECTOR
Weatherized Standard
RJ45 Ethernet Connector
RF INPUT
Type N, 50
Ω
2.02 - 2.12 GHz
S-Band Input.
RF IN MON
Type N, 50
Ω
.
10MHz INPUT
SMA (female) 50
Ω
Insert External 10MHz)
Reference here (+2 to +8 dBm).
10MHz OUTPUT
SMA, 50
Ω
Output level =
+2 to +8 dBm ±1.0 dB.
7.88
6.62
4.2
J6
.
DS1 - POWER LED
Lights GREEN when DC voltage is
present from AC power supply.
15.875
12.00
15.5
7.50
1/4-20 Tapped Thru, 4 Places
STATUS/CONTROL
CONNECTOR
Weatherized
MS3112E14-18S
18 pin connector.
See Table 2.6
5.775
5.500
• • • • •
• • • •
• • •
• • • •
• •
STATUS /
CONTROL
4116-21T23 Manual, Rev. B
Page 15