background image

Instruction Manual

          

Model 3116-T71-184   

    

Multi-Band Translator

   

May 2016,   Rev. B

   

  

MENU

EXECUTE

MODEL 3116

C

ROSS 

T

ECHNOLOGIES INC.

MUTE

REMOTE POWER

ALARM

MULTI-BAND TRANSLATOR

B3 12.75>11.70 GHz  
G=10.0  Ref=INT     

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be 
reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating 
the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, 
equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005 

FAX  (770) 886-7964

Toll Free  888-900-5588

WEB  www.crosstechnologies.com 

E-MAIL  [email protected]

Содержание 3116-T71-184

Страница 1: ...Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be s...

Страница 2: ...are warranted against defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cro...

Страница 3: ...range The 3116 is powered by a 100 240 10 VAC power supply and housed in a 1RU rack mount chassis 1 75 H X 19 0 W X 19 0 deep MENU EXECUTE MODEL 3116 CROSS TECHNOLOGIES INC B3 12 75 11 70 GHz G 10 0...

Страница 4: ...2 Tone 40 dBC Signal Dependent 50 dBm signal indep 10 dBm in 0 dBm output Spurious Inband 45 dB minimum at maximum gain and 0 dBm out Input to Output Isolation 20 3 dB maximum 20 to 40 dB variable in...

Страница 5: ...47 63 Hz 25 watts maximum Power Direct readout LCD Pushbutton Switches or via Ethernet M C or Monitor and Control Connector Gain Band 10M Frequency 0 to 50 degrees C Operating 30 to 60 degrees C Non o...

Страница 6: ...1 7 to 12 8 GHz x 1 to select internal reference where aaCEx Set External Reference x 0 to unmute the output x 1 to mute the output where aaCMx Set Mute Range 20 to 40 dB variable in 1 1 dB steps xxx...

Страница 7: ...z 1 mute is on Returns aaSAwxyz where aaSA Unit Status x 3 if in auto select mode x 7 to select band 7 in 17 3 to 18 4 GHz Out 11 7 to 12 8 GHz x 4 to select band 4 in 13 75 to 14 85 GHz out 10 7 to...

Страница 8: ...5 VDC power supply provides power for the assemblies The 3116 T71 184 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 3116 T71 184 is assembled POWER SUPPLY VCO...

Страница 9: ...emale connector J7 J2 J7 ETHERNET CONNECTION Option W8 RJ45 Ethernet Connector RF MON J1 RF IN 5 85 6 725 GHz 12 75 13 75 GHz 12 75 13 25 GHz 13 75 14 85 GHz 13 75 14 85 GHz 17 3 18 4 17 3 18 4 SMA fe...

Страница 10: ...indicates presence of DC power DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode Does not function...

Страница 11: ...ut level is always within the range of 20 to 40 dB See Table 2 0 6 Select either INT for internal 10 MHz ref or EXT for external 10 MHz 2 to 8 dBm reference that is inserted at J2 7 AC Fuse The fuse i...

Страница 12: ...t to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 3116 T71 184 2 5 2 Ethernet Configuration Each 3116 T71 184 must be configured with an appropriate IP address Netmask an...

Страница 13: ...Gateway address with delimiter dots example 192 168 192 47 2 5 3 Webpage M C Enter the following address in a web browser to access the M C webpage http ip address of 41xx serial 0 setup htm where ip...

Страница 14: ...ng Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock from...

Страница 15: ...MP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of SN...

Страница 16: ...Figure 2 E Device Server Configuration Menu 3116 T71 184 Manual Rev B Page 16 05 16 16...

Страница 17: ...on of the Menu Execute switch and must also end with the operation of the Menu Execute switch verified by the Save Settings Menu If this sequence is not followed none of the changes will take effect I...

Страница 18: ...tely 30 seconds and the system will return to the normal operating mode or scroll to R and push the menu Execute switch and select NO in the SAVE SETTINGS window To change the BAND Operate the Menu Ex...

Страница 19: ...dB steps and then push the Menu Execute switch to get to the Gain setting GAIN 10 R Press the Up Down switch to change the gain in 1 or 10 dB steps GAIN 11 R By using the horizontal rocker switch the...

Страница 20: ...cations Interface Option Q Menu 7 Interior Temperature Save Settings At the end or when R is selected from any of the above menus ON POWER UP NORMAL DISPLAY PUSHING MENU EXECUTE SEQUENCE FPC 4 00 Load...

Страница 21: ...operation of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circui...

Страница 22: ...NC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 3116 T71 184 Manual Rev...