2.3

  

Front Panel Controls and Indicators - 

The following are the front panel controls and indicators.

MENU

EXECUTE

2001.125   2110.500

REMOTE

POWER

LCD  FRONT PANEL DISPLAY

Shows parameter selection and 
frequency and gain settings
for channels 1, 2, 3, & 4.

S1 - MENU/EXECUTE BUTTON

Press this to get into Program mode 
and  to execute any changes.

DS6 - POWER LED

Green LEDs indicates 
presence of DC power.

DS1 - REMOTE LED

Yellow LEDs indicates 
remote operation.

S2 - MULTI-FUNCTION SWITCH

Vertical toggle switch that controls 
values in the Menu items when in 
program mode. Does not function 
in the normal display mode.

S3 - MULTI-FUNCTION SWITCH

Horizontal toggle switch that 
controls which values are being 
adjusted. Does not function in the 
normal display mode.

ALARMS 

-------- CH 1 --------    -------- CH 2 ---------

DS2 -  ALARM LEDs

Red LEDs indicate 
Downconverter alarms for
channels 1, 2, 3, & 4.

1

2

3

4

-------- CH 3 --------    -------- CH 4 --------

 

2210.000   2301.750

 

FIGURE 2.3    2416-x25  Front Panel Controls and Indicators

FRONT PANEL (2416-425 - Four Channel show above)

 

2416-425  Manual

                              Page 13

                                           11/17/21

Содержание 2416 25 Series

Страница 1: ...nel Data drawings and other material contained herein are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes...

Страница 2: ...ucts are warranted against defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at...

Страница 3: ...ower supply and is contained in a 1 3 4 X 19 X 16 rack mount chassis 2416 425 Four 4 Channels 2416 325 Three 3 Channels 2416 225 Two 2 Channels 2416 125 One 1 Channel MENU EXECUTE MODEL 2416 CROSS TEC...

Страница 4: ...teps Gain Range adjustable 0 dBm Output 1 dB compression 70 18 MHz Frequency 75 18 dB See Table 2 2 for connector options Impedance Return Loss 15 dB maximum gain Noise Figure Max 2000 to 2500 MHz Fre...

Страница 5: ...r Mounted Cooling Fan X1002 x W113 W8 W18 W28 W828 Redundant Power Supply R Available Options 140 36 MHz W140 x Ethernet with TCP IP Telnet W28 See TABLE 2 2 Connectors Impedance 10 C to 40 C Specific...

Страница 6: ...le DB 9 PC Com Port Male DB 9 2416 x25 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 female J10 Pinouts RS 232C 422 485...

Страница 7: ...el number xxx gain to nearest 1 0 dB e g 14 14 dB Get spectrum inversion setting aa iSX Returns iSXx where i 1 2 3 or 4 designating the channel number x 0 for non invert 1 for invert Get reference sta...

Страница 8: ...x subnet mask Get channel base parms aa iS1 Returns iS1tfffffffgggha where i 1 2 3 or 4 designating the channel number t channel type 0 for unused 1 for upconverter 2 for downconverter fffffff frequen...

Страница 9: ...le 1 2 2416 x25 Commands Command Syntax Description Set Channel Frequency aa iCFxxxxxxx where i 1 2 3 or 4 designating the channel number xxxxxxx frequency in KHz Set Channel Gain aa iCGxx where i 1 2...

Страница 10: ...een units is recommended if multiple Quad channel units are to be stacked in the same rack Fan Option W113 may also be selected for enviroments with poor air flow and or where additional space between...

Страница 11: ...ssis A switching 12 24 5 VDC power supply provides power for the assemblies The 2416 x25 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 2416 x25 is assembled PO...

Страница 12: ...s for other options 2416 425 Manual Page 12 11 17 21 AC GND J11 J12 AND MONITOR CONTROL 1 5 2 3 4 6 7 8 9 CHANNEL 4 RF IN J10 J9 RF OUT CHANNEL 3 RF IN J8 J7 RF OUT CHANNEL 1 RF IN J2 J1 RF OUT 10 MHZ...

Страница 13: ...LED Yellow LEDs indicates remote operation S2 MULTI FUNCTION SWITCH Vertical toggle switch that controls values in the Menu items when in program mode Does not function in the normal display mode S3 M...

Страница 14: ...s 6 Be sure DS6 green DC Power PSA PSB is on and DS2 red Alarm is off Figure 2 3 7 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and is inserted in the far slot in the drawer below the AC...

Страница 15: ...ave and YES If you do not wish to save any settings you can either select Save and NO or you can NOT press the Menu Execute switch and simply do nothing for approximately 30 seconds and the unit will...

Страница 16: ...NTIL YOU GO TO THE SAVE MENU AND INDICATE YOU WANT TO SAVE THE CHANGES 2 5 3 Gain Changes When you get to this menu note that the gain changes will be made as you make them but if you do not wish to s...

Страница 17: ...NGS EXT REF INT SAVE SETTINGS Y N SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL OTHER SETTINGS REF OFFSET 0000 OTHER SETTINGS REMOTE ON OTHER SETTINGS INTERFACE RS232 RS485 ADD...

Страница 18: ...the 2416 x25 Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 2416 x25 3 2 Ethernet Configuration Each product must be configured with an appropriate IP add...

Страница 19: ...nfiguration Manager web page In the left frame of the configuration manager click on Network to display the Network Settings screen Enter the IP address Subnet mask and Gateway address with delimiter...

Страница 20: ...Figure 3 2 Network Settings Web Page Screen Example above shows Network Settings Screen for Model 2416 425 2416 425 Manual Page 20 11 17 21...

Страница 21: ...http ip address serial 0 setup htm where ip address is the IP address of the 2416 x25 Figure 3 3 example below shows the web page from model 2416 425 frequency converter Figure 3 3 Model 2416 x25 Web...

Страница 22: ...d to access the SNMP configuration menu Figure 3 4 Telnet Settings in Hyper Terminal Once the Telnet connection is established you will be prompted to Press Enter for Setup Mode Press enter and a menu...

Страница 23: ...ber of authorized IP addresses of SNMP Managers It is not required to enter IP Addresses of SNMP Managers Figure 3 5 Device Server Configuration Menu Once you have completed you SNMP set up select ite...

Страница 24: ...IES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2416 425 Manual Pa...

Отзывы: