1.3  Monitor and Control Interface

A)   Remote serial interface

Protocol: RS-232C,  9600 baud rate, no parity, 8 data bits, 1 start bit,  and 1 stop bit.

(RS-232C, RS-422, or RS-485)

 

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

Female DB-9
PC Com Port

Male DB-9

2416-x02I M&C Port

M&C Cable Diagram -  Cross Technologies Frequency Converters

RX

RX

TX

TX

DTR

SG

DSR

RTS

CTS

SG

Connector: Rear panel, DB-9 female

J10  Pinouts  (RS-232C/422/485)

Pinouts

  (RS-232C/422/485)

Pin

Function

1

Rx-

2

Rx+ (RS-232C)

3

Tx+ (RS-232C)

4

Tx-

5

GND

6

Alarm Relay: Common

7

Alarm Relay: Normally Open

8

Not Used

9

Alarm Relay: Normally Closed

2416-402I  Manual, Rev. C 

                              Page 6

                                           03/22/21

Содержание 2416 02I Series

Страница 1: ...anel Data drawings and other material contained herein are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes...

Страница 2: ...s are warranted against defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cr...

Страница 3: ...402I is powered by a 100 240 10 VAC 47 63 Hz power supply and is contained in a 1 3 4 X 19 X 16 rack mount chassis 2416 x02I Four 4 Channels 2416 302I Three 3 Channels 2416 202I Two 2 Channels 2416 1...

Страница 4: ...n 70 18 MHz Frequency 75 18 dB See Table 2 2 for connector options Impedance Return Loss 15 dB maximum gain Noise Figure Max 950 to 2150 MHz Frequency 75 10 dB See Table 2 2 for connector options Impe...

Страница 5: ...1002 x W113 Ethernet with TCP IP Telnet W28 LNB Voltage 24 VDC 0 4 amps L1 Available Options 140 36 MHz W140 x Ethernet with Web Browser SNMP W18 See TABLE 2 2 Connectors Impedance 10 C to 40 C Specif...

Страница 6: ...DB 9 PC Com Port Male DB 9 2416 x02I M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 female J10 Pinouts RS 232C 422 485...

Страница 7: ...gain to nearest 1 0 dB e g 14 14 dB Get spectrum inversion setting aa iSX Returns iSXx where i 1 2 3 or 4 designating the channel number x 0 for non invert 1 for invert Get reference status aaSE Retu...

Страница 8: ...fffgggha where i 1 2 3 or 4 designating the channel number t channel type 0 for unused 1 for upconverter 2 for downconverter fffffff frequency in KHz ggg gain to nearest 1 0 dB e g 25 25 dB h spectrum...

Страница 9: ...x02I Commands Command Syntax Description Set Channel Frequency aa iCFxxxxxxx where i 1 2 3 or 4 designating the channel number xxxxxxx frequency in KHz Set Channel Gain aa iCGxx where i 1 2 3 or 4 de...

Страница 10: ...units is recommended if multiple Quad channel units are to be stacked in the same rack Fan Option W113 may also be selected for enviroments with poor air flow and or where additional space between un...

Страница 11: ...A switching 12 24 5 VDC power supply provides power for the assemblies The 2416 x02I can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 2416 x02I is assembled POWER...

Страница 12: ...20 to 10dBm BNC female J6 RF IN 950 2150 MHz input 50 to 20 dBm Type F female see Table 2 2 VDC on RF Lights yellow when 24 VDC is inserted on J5 J7 RF OUT 70 MHz Output 20 to 10dBm BNC female J8 RF...

Страница 13: ...ellow LEDs indicates remote operation S2 MULTI FUNCTION SWITCH Vertical toggle switch that controls values in the Menu items when in program mode Does not function in the normal display mode S3 MULTI...

Страница 14: ...Be sure DS6 green DC Power PSA PSB is on and DS2 red Alarm is off Figure 2 3 7 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and is inserted in the far slot in the drawer below the AC inp...

Страница 15: ...and YES If you do not wish to save any settings you can either select Save and NO or you can NOT press the Menu Execute switch and simply do nothing for approximately 30 seconds and the unit will retu...

Страница 16: ...L YOU GO TO THE SAVE MENU AND INDICATE YOU WANT TO SAVE THE CHANGES 2 5 3 Gain Changes When you get to this menu note that the gain changes will be made as you make them but if you do not wish to save...

Страница 17: ...SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL OTHER SETTINGS REF OFFSET 0000 OTHER SETTINGS REMOTE ON OTHER SETTINGS INTERFACE RS232 RS485 ADDR 00 R R R R R PUSHING MENU EXECUTE SEQUENCE ON POWER U...

Страница 18: ...2416 x02I Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 2416 x02I 3 2 Ethernet Configuration Each product must be configured with an appropriate IP addres...

Страница 19: ...guration Manager web page In the left frame of the configuration manager click on Network to display the Network Settings screen Enter the IP address Subnet mask and Gateway address with delimiter dot...

Страница 20: ...Figure 3 2 Network Settings Web Page Screen Example above shows Network Settings Screen for Model 2416 402I 2416 402I Manual Rev C Page 20 03 22 21...

Страница 21: ...ip address serial 0 setup htm where ip address is the IP address of the 2416 x02I Figure 3 3 example below shows the web page from model 2416 402 frequency converter Figure 3 3 Model 2416 x02I Web Pag...

Страница 22: ...o access the SNMP configuration menu Figure 3 4 Telnet Settings in Hyper Terminal Once the Telnet connection is established you will be prompted to Press Enter for Setup Mode Press enter and a menu of...

Страница 23: ...of authorized IP addresses of SNMP Managers It is not required to enter IP Addresses of SNMP Managers Figure 3 5 Device Server Configuration Menu Once you have completed you SNMP set up select item 9...

Страница 24: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2416 402I Manual Rev...

Отзывы: