background image

6/25/99 HWW

REV  B

10 
MHZ 
IN

TTL 
CONV.
U15, U1

PLL
U2,U4 

HIGH

TERM

LEVEL 
DET.
U7, U8

12.288 MHz Monitor
(Front Panel)

DIVI-
DER 

U9,
U11, 
U12

256

128

64

192

96

CLOCK A
RS422

U14

4

5

CLOCK B
RS422

16

U14

17

AUTO

V+

V+

EXT

INT

MANUAL 
ALARM

UP
U3

INT / EXT 
CLOCK

PIN 2

PIN 3

VCXO INT. 
FREQ. R20

12.288 
MHZ  VCXO

+5V 
REG 
VR3

-15 A

-15B

+15 A

+15B

-12 

+12

+5 

-12V 
REG 
VR1

+12V 
REG
VR2 

U10

U5

U6, 
Q2

256

128

64

192

96

INT /EXT 
CLOCK
(RED/ 
GREEN)

REF. 
ALM
(RED/ 
GREEN)

PLL ALM
(RED)

ALARM

PLL  LOCK

LEVEL

MANUAL

MANUAL OC

ALARM CC

MANUAL 
ALM
(RED)

INT / EXT CLOCK

DS3          DS2             DS1     
DS4

S1

JP4

JP5

JP1

JP2

FIGURE 3.1 2099-42 BLOCK DIAGRAM

2099-42 manual Rev. A

Page 11

10/27/2005

Содержание 2099-42

Страница 1: ...oses of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part First Edition Octobe...

Страница 2: ...rials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacin...

Страница 3: ...manually selects internal or external lock to 10 MHz control of the VCXO Diodes on the DC inputs allow operation from redundant power supplies An open collector indicates Manual operation and relay c...

Страница 4: ...or AUTO select Int Freq Adjusts frequency of internal VCXO when not locked to external 10 MHz INT EXT LED LED lights RED if VCXO controlled internally Green if locked to external 10 MHz MAN LED LED li...

Страница 5: ...nput Output Signals Figure 2 3 shows the input and output signals to the 2099 42 Table 2 1 is a description of the connectors and J4 pin functions 2 4 Jumper Settings Figure 2 4 and Table 2 2 show jum...

Страница 6: ...moved the PLL will lose lock and will force the internal VCXO to have the frequency set by front panel potentiometer R20 R20 DOES control the VCXO in this mode if it has automatically switched to Inte...

Страница 7: ...ll light occasionally depending on how far off in frequency the VCXO is set from locking to it DS3 EXTERNAL REFERENCE PRESENT LED Lights GREEN when 10 MHz external reference is present and RED if belo...

Страница 8: ...RS422 Clock A output 6 NOT USED 7 NOT USED 8 15 VDC Backup In 180 ma max 9 15 VOLTS 180 ma max from J2 Main Power Supply 10 MAJOR Alarm relay output Open or short selectable to pin 12 if PLL alarm or...

Страница 9: ...EQUENCY N A N A N A JUMPER POSITION SELECTS 64 TO 256 CLOCK FREQUENCY CH A JP5 CLOCK A FREQUENCY N A N A N A JUMPER POSITION SELECTS 64 TO 256 CLOCK FREQUENCY CH B TABLE 2 2 JUMPER DESCRIPTIONS K1 R20...

Страница 10: ...and clock B RS422 outputs The external 10 MHz reference frequency also goes to buffer amplifier U7 which drives peak detector CR8 and then goes to op amp U8 the output of which provides a 5 signal if...

Страница 11: ...T MANUAL ALARM UP U3 INT EXT CLOCK PIN 2 PIN 3 VCXO INT FREQ R20 12 288 MHZ VCXO 5V REG VR3 15 A 15B 15 A 15B 12 12 5 12V REG VR1 12V REG VR2 U10 U5 U6 Q2 256 128 64 192 96 INT EXT CLOCK RED GREEN REF...