background image

2083-0703 Translator

1.0  General

1.1  Equipment Description

The 2083-0703 Translator converts 720 ± 75 MHz to 370 ± 75 MHz with a high side LO (inverted spectrum). 
Push button switches select the gain, and other parameters. Front panel LEDs provide indication of DC power 
(green), PLL alarm (red), and Remote operation (yellow). Gain is adjustable over a 0 to 20 dB range in 1±1 dB 
steps locally via front panel switches and remotely via M&C interface. Parameter selection and gain settings 
appear on the LCD display. Connectors are Type N female for RF input and BNC for IF (RF Out) and optional 
external reference input and output. The external 10 MHz Option E  includes a 10 MHz output connector which 
contains either the internal or external 10 MHz reference signal. It is powered by a 100-240 ± 10% VAC power 
supply, and in a 1 3/4” X 19” X 16” rack mount chassis.

MENU

EXECUTE

MODEL 2083

C

ROSS 

T

ECHNOLOGIES INC.

720>370   G=20
        REF=INT

REMOTE

ALARM 

POWER

TRANSLATOR

FRONT PANEL

AC

GND

J3

J10

J18

J2

RF OUT

10 MHZ REF

10 MHZ

AND

MONITOR

EXT REF

CONTROL

J1

RF IN

OUTPUT

INPUT

J20

1

2

3

4

6

7

8

9

REAR PANEL  (Shown with optional external reference input/output and Ethernet) 

FIGURE 1.1     Model 2083-0703  Front & Rear Panels

720

± 75
MHz

IN

CONTROLLER

720>370    G=20
        REF=INT

EXT

10 MHz*

* = OPTIONAL

VAR 

ATT

INT

10 MHz

2083-0703 

Block Diagram

370

± 75
MHz

IN

1.09
GHz

FIGURE 1.2      Model 2083-0703 Block Diagram

2083-0703 Manual, Rev. 0

 

                Page 3

    

       08/24/15

Содержание 2083-0703

Страница 1: ...reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to includ...

Страница 2: ...r Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall...

Страница 3: ...and output The external 10 MHz Option E includes a 10 MHz output connector which contains either the internal or external 10 MHz reference signal It is powered by a 100 240 10 VAC power supply and in...

Страница 4: ...B at Fc 1 1 dB steps manually adjustable Gain Range 370 75 MHz Frequency 50 12 dB Impedance Return Loss 15 dBm minimum No Damage Input Level 50 to 25 dBm Input Level 720 75 MHz Frequency 50 12 dB Impe...

Страница 5: ...without notice Cross Technologies Inc 2015 Contact Cross Technologies Inc for other options Ethernet with Web Browser SNMP W18 Communication Interface Standard RS232 Ethernet with Web Browser W8 Ether...

Страница 6: ...8 9 Female DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 female Pinouts RS 485 42...

Страница 7: ...Comma ands Commands Command Syntax Description Set Transmit Gain aaC3xx where xx 2 characters Range 0 to 20 0 dB to 20 dB in 1 1 dB steps Enable External 10MHz aaCEx where x 0 to disable External 10M...

Страница 8: ...e operation of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circ...

Страница 9: ...h high by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2083 0703 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how t...

Страница 10: ...EF INPUT J3 EXT REF INPUT 3 3 dB 10 MHz Ext Ref Input FIGURE 2 1 2083 0703 Rear Panel I O s TABLE 2 1 J J10 TABLE 2 1 J10 Pinouts Pin Function 1 Rx 2 RS232C 3 RS232C 4 Tx 5 GND 6 Alarm Relay Common 7...

Страница 11: ...s not function in the normal display mode MENU EXECUTE 720 370 G 20 REF INT POWER ALARM S3 MENU EXECUTE BUTTON Press to get into Program mode and to execute any changes DS6 ALARM LED Red LED indicates...

Страница 12: ...is off Figure 2 2 5 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and is inserted in the far slot in the drawer below the AC input as shown in Figure 2 3 There is a spare fuse in the near...

Страница 13: ...R is selected in any of the above menus or when operator reaches the end Alarm indications appear on the LEDs see figure 2 2 All program changes must start with the operation of the Menu Execute switc...

Страница 14: ...the operator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute...

Страница 15: ...t or right Pressing the Up Down switch down will toggle the display digit selected until you have the desired gain NOTE THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS HOWEVER THE VALUE WILL NOT BE...

Страница 16: ...SPLAY PUSHING MENU EXECUTE SEQUENCE REV 1 00 720 370 G 20 REF INT REMOTE OFF EXT REF OFF SCROLL SCROLL PUSH BUTTON PUSH BUTTON Power Up Normal Display Menu 1 Gain 0 to 20 Menu 2 Set Unit to Remote Ope...

Страница 17: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2083 0703 Manual Rev...