B) Status Requests
Table 1.1 lists the status requests for the 2016-02-1200 and briefly describes them.
*
PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when RS-485, (OPTION-Q), is selected.
TABLE 1.1 2016-02-1200 SStatus
2016-02-1200 S
tatus Requests
TABLE 1.1 2016-02-1200 Status Requests
Command
Syntax*
Description
Command Status
{aaS1}
Returns {aaS1bbbbbbbccA} where:
• bbbbbbb = Rx frequency
• cc = Rx gain (•ccc if unit has option Z5)
• A = summary alarm; 1=alarmed, 0=normal
10MHz Ref Status
{aaS2}
Returns {S2ER} where:
• E = 1 - external 10 MHz switched in
• R = 1 - 10 MHz ref inserted on RF input connector
LNB Current
{aaS3}
Returns {S3eee} where:
(option L only)
• eee = LNB current (000 to 500 = 0 to .500 A)
2016-02-1200 Manual, Rev. 0
Page 7
05/13/19