2.5.5  Alarm Indications

An alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock.  The Mute 
LED will light if you select Mute and the Remote LED will light when you select the Remote mode.

ON POWER UP

NORMAL DISPLAY

PUSHING MENU/EXECUTE SEQUENCE

REV 1.00

F = 1975.125   

G = 30.0

F = 1875

SCROLL <>

SCROLL 

PUSH BUTTON

REMOTE  OFF

EXT REF   OFF

SCROLL <>

SCROLL 

PUSH BUTTON

PUSH BUTTON

Power Up

Normal Display

Menu 1  Frequency

Menu 2  Gain (00 to +30)

Menu 3 Set Unit to 
Remote Operation

Menu 4 Select External 
10 MHz Reference

Menu 5 Select 10MHz 
Reference Out

Menu 6 Set Remote Mode
(option -Q)

Menu 7 Set RS-485 Address 
(option -Q) (options, -W8,-W18,-W28)

Save? When “R” is selected 
or at the end of the menu options

G = 30

SCROLL <>

SCROLL 

PUSH BUTTON

SCROLL <>

SCROLL 

PUSH BUTTON

SAVE SETTINGS?   Y N 

SCROLL <>

PUSH BUTTON

 R

 R

 R

 R

REF OUT   OFF

SCROLL <>

SCROLL 

PUSH BUTTON

 R

RS 485    OFF

SCROLL <>

SCROLL 

PUSH BUTTON

 R

ADDRESS = 00

SCROLL <>

SCROLL 

PUSH BUTTON

 R

FIGURE 2.5   Menu Display and Sequence

2016-02-1200  Manual, Rev. 0 

                     Page 18   

                                           05/13/19

Содержание 2016-02-1200

Страница 1: ...c but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include...

Страница 2: ...a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or...

Страница 3: ...and output External 10 MHz is standard A 10 MHz output connector contains either the internal or external 10 MHz reference signal whichever is selected by the user The 2016 02 1200 is powered by a 10...

Страница 4: ...djustable 0 dBm maximum Gain Output 1 dB Compression 1200 100 MHz Frequency 50 14 dB Impedance Return Loss 50 to 20 dBm Input Level Range 20 dB maximum gain Noise Figure Max 950 to 2150 MHz Frequency...

Страница 5: ...notice Cross Technologies Inc 2019 Available Options Ethernet with Web Browser TCP IP Telenet W28 LNB Voltage 24VDC 0 4 amps L Connector Options Ethernet with Web Browser WB W8 High Stability 0 01 pp...

Страница 6: ...male DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 male J10 Pinouts RS 232C 422 4...

Страница 7: ...us Requests TABLE 1 1 2016 02 1200 Status Requests Command Syntax Description Command Status aaS1 Returns aaS1bbbbbbbccA where bbbbbbb Rx frequency cc Rx gain ccc if unit has option Z5 A summary alarm...

Страница 8: ...le 1 2 2016 02 1200 Commands Command Syntax Description Set Receiver Frequency aaC2xxxxxxx where xxxxxxx 7 characters Range 0950000 to 2150000 kHz in 125 kHz steps 100 kHz steps if unit has option X1...

Страница 9: ...operation of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circu...

Страница 10: ...6 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2016 02 1200 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 2016...

Страница 11: ...PUT DS8 LNB ALARM LED option L Lights yellow when 24 VDC LNB voltage is present on RF IN J2 center pin J18 10 MHz REF OUTPUT 10 MHz reference output 75 BNC female connector 1 5 2 3 4 6 7 8 9 J20 J20 E...

Страница 12: ...downconverter alarm DS6 POWER LED Green LED indicates presence of DC power DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the Menu...

Страница 13: ...gs 6 Be sure DS6 green DC Power is on and DS3 red Alarm is off Figure 2 3 7 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and is inserted in the far slot in the drawer below the AC input a...

Страница 14: ...emote mode option Q Menu 7 Set RS 485 address option Q Menu 8 LNB Current option L Save Menu When go to end Alarm indications appear on the LEDs see figure 2 3 All program changes must start with the...

Страница 15: ...ay desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switch 2 Hori...

Страница 16: ...ng the downconverter frequency F 197 5 R Pressing the Up Down switch down will toggle the display to F 187 5 R By using the horizontal rocker switch the cursor can be moved left or right F 1875 R NOTE...

Страница 17: ...the cursor location G 20 R By using the horizontal rocker switch the cursor can be moved left or right Pressing the Up Down switch will toggle the display digit selected until you have the desired ga...

Страница 18: ...Up Normal Display Menu 1 Frequency Menu 2 Gain 00 to 30 Menu 3 Set Unit to Remote Operation Menu 4 Select External 10 MHz Reference Menu 5 Select 10MHz Reference Out Menu 6 Set Remote Mode option Q Me...

Страница 19: ...NC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2016 02 1200 Manual Rev...

Отзывы: