1.1 Equipment Description
The 2016-02-1200 Downconverter converts 950 to 2150 MHz to 1200 MHz in 125 kHz steps with low group
delay and flat frequency response. Synthesized local oscillators (LO) provide frequency selection. Multi-
function switches select the input frequency, gain, and other parameters. Front panel LEDs provide indication
of DC power, PLL alarm or Remote operation. Gain is adjustable manually (MGC) over a 0 to +30 dB range.
The frequency and gain are remotely selectable. Parameter selection and frequency and gain settings appear on
the LCD display. Connectors are Type F female for the RF, and BNC female for the IF and external 10 MHz
reference input and output. External 10 MHz is standard. A 10 MHz output connector contains either the
internal or external 10 MHz reference signal whichever is selected by the user. The 2016-02-1200 is powered
by a 100-240 ±10% VAC, 47-63 Hz power supply, and is contained in a 1 3/4” X 19” X 16” rack mount
chassis.
MENU
EXECUTE
MODEL 2016
C
ROSS
T
ECHNOLOGIES INC.
REMOTE
POWER
ALARM
DOWNCONVERTER
F = 1975.125
G = 30.0
FRONT
AC
GND
J3
J10
J18
J2
RF IN
10 MHZ REF
10 MHZ
AND
MONITOR
EXT REF
LNB FUSE
F1
CONTROL
J1
IF OUT
OUTPUT
INPUT
DS8
VDC on RF
J20
1
5
2
3
4
6
7
8
9
REAR
FIGURE 1.1 Model 2016-02-1200 Front and Rear Panels
1200 ±100
MHz OUT
950
to
2150
MHz
IN
2800 MHz BP
4000
MHz
3750
to
4950
MHz
900 to 2200
MHz HP/LP
1400 MHz LP
CONTROLLER
F=1975.125
G=30
2016-02-1200 Downconverter Block Diagram
VAR
ATT
EXT
10 M
INT/EXT
10 M
FIGURE 1.2 Model 2016-02-1200 Downconverter Block Diagram
2016-02-1200 Manual, Rev. 0
Page 3