background image

1.2   Technical Specifications

TABLE 1.0 1582-725 RF Switch Specifications*

Switch Characteristics

Impedance

75

Type/Configuration

Non-Latching Relay, DPDT 

Insertion Loss   

1.5 dB max., 

1.0 dB, typ, DC to 1.5 GHz

2.5 dB max., 

2.0 dB, typ, 1.5 to 2.5 GHz

Frequency Response

±0.5 dB, any 40 MHz BW, DC to 2.5 GHz

Return Loss

  

12 dB max., 

14 dB, typ, DC to 1.5 GHz

10 dB max., 

12 dB, typ, 1.5 to 2.5 GHz

Isolation

  

-55 dB max., 

-60 dB, typ, DC to 1.5 GHz

-45 dB max., 

-50 dB, typ, 1.5 to 2.5 GHz

Switch time

  

10 milliseconds

Controls
MANUAL SELECT Manually select CH1, CH2, or Auto operation.  If operating in the ICS mode, the last 

channel manually selected (CH1 or CH2) will be the initial channel if both channel 
alarms are clear or both channels are in alarm.

SWITCH RESET

Resets switch to CH1 if it is good and switch is in the latch mode, 
Also Resets REMOTE by returning operation to Auto

Indicators, LEDs
CH1 ON-LINE

Turns green when Channel 1 is selected

CH2 ON-LINE

Turns green when Channel 2 is selected

MANUAL 

Turns red when the Manual Select switch manually selects channel 1 or 2.

ALARM CH1

Turns red when an external alarm input (closure or open, selectable)

ALARM CH2

Turns red when an external alarm input (closure or open, selectable)

POWER 1

Turns green when power is applied to AC1 input on the rear panel 

POWER 2

Turns green when power is applied to AC2 input on the rear panel 

REMOTE

Turns amber when REMOTE control is active

Other
Mechanical

19 inch standard chassis 1.75”high X 12” deep

Power

 

Redundant power supplies; 100 - 240 ±10% VAC, 47 - 63Hz, 30 watts

*Specifications subject to change without notice

1582-725 Manual, Rev. B

 

 

  Page 4

    

          4/10/14

Содержание 1582-725

Страница 1: ...proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770...

Страница 2: ...nship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misus...

Страница 3: ...lear Factory set mode is generally 1 CH1 Prime Mode When power is first applied and there are no alarms CH1 is selected On power loss CH2 is the selected channel The Manual Select switch and contact closures to Remote Select pins when in Auto select CH1 or CH2 independent of alarms LEDs indicate alarm and switch conditions for CH1 and CH2 REMOTE or MANUAL operation and power on RF connectors are B...

Страница 4: ...ls are in alarm SWITCH RESET Resets switch to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to Auto Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected CH2 ON LINE Turns green when Channel 2 is selected MANUAL Turns red when the Manual Select switch manually selects channel 1 or 2 ALARM CH1 Turns red when an external alarm input closure ...

Страница 5: ...s J7A J7B Monitors and Controls Connectors J7A TOP J7B BOTTOM Function Pin Description ALARM 1 IN 13 Ground or Open selectable by JP2 JP102 gives CH1 alarm ALARM 2 IN 14 Ground or Open selectable by JP2 JP102 gives CH2 alarm REMOTE 1 IN 1 When in AUTO momentary ground on this pin selects CH1 REMOTE 2 IN 2 When in AUTO momentary ground on this pin selects CH2 REMOTE RESET IN 4 When in LATCH mode gr...

Страница 6: ...sition switch as follows LEFT manually select Channel 1 CENTER AUTO switch position determined by alarm and remote closures RIGHT manually select Channel 2 Switch RESET Resets switch to Channel 1 if it is good and switch is in the latch mode Also resets REMOTE selection to normal AUTO operation Common for the Chassis Common for the Chassis Item Description POWER 1 LED Turns green when power is app...

Страница 7: ...de on off 3 pin jumper effective when JP1 is in the non dot position With JP3 in the dot and JP1 in the non dot when channel 1 alarms the 1582 14 switch switches to channel 2 and stays there until the reset button is pushed on the front panel or by an external closure to ground on the remote RESET pin on J8 and then it switches to channel 1 If channel 1 alarms are cleared If in the ICS mode and or...

Страница 8: ...ote 1 or Remote 2 pins on J8 and then grounding the Remote reset pin on J8 causing the 1582 14 to go back to Auto in the channel last selected remotely if both channel alarms are clear or both channels are in alarm The initial channel can also be selected if both channel alarms are clear or both channels are in alarm S3 S103 positions 1 2 3 4 to OFF ICS is disabled Minimum Auto switching Return to...

Страница 9: ...ALL SWITCH POSITIONS IN THE ON SIDE POWER SUPPLY 2 POWER SUPPLY 1 SHOWN IN THE ICS MODE S4 S5 JP2 JP3 JP15 JP16 JP17 JP18 JP1 JP104 JP102 JP103 JP101 S3 S103 JP10 S104 S105 JP109 JP110 FIGURE 2 3 1582 725 PCB Settings Parts Locations 1582 725 Manual Rev B Page 9 4 10 14 ...

Страница 10: ...te selection after return to Auto if both channel alarms are clear or both channels are in alarm Auto switching occurs only if current channel alarms and the other channel is clear Non dot SWITCH A JP4 SWITCH B JP104 Dot SWITCH A JP1 JP2 JP3 SWITCH B JP101 JP102 JP103 S3 SWITCH A S103 SWITCH B ALL TO ON Factory set mode is generally 1 CH1 Prime Mode 2 7 Operation a Set the on board controls as des...

Страница 11: ... equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring Appropriate consideration of equipment name plate rating should be used when addressing this concern F Reliable Ea...

Страница 12: ...ES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 1582 725 Manual Rev B Page 12 4 10 14 ...