2.0 Installation

2.1 Input/Output Connectors

 - 

The following are the input and output connectors.

AC1

AC2

1

14

J7

J6

GND

J5

J4

J3

J1

J2

A1

A

A2

B1

B2

B

J7-MONITORS 
& CONTROLS

AC1 
POWER IN 1
1.5 A FUSE 

 AC2 
POWER IN 2
1.5 A FUSE 

J4-
SW A 
RF 2 

J6-
SW A 
RF 1 

J5- SW A 
SWITCHED 
RF  

J1 -
SW B 
RF 2

J3 -
SW B 
RF 1 

J2 - SW B 
SWITCHED 
RF  

FIGURE 2.0 1582-70L REAR PANEL

 

TABLE 2.0 INPUT / OUTPUT CONNECTORS (FIGURE 2.0)

J1, J2, J3, J4, J5, J6 - RF CONNECTORS (FIGURE 2.0)

J7 - MONITORS AND CONTROLS CONNECTOR (FIGURE 2.0)

Function

Pin #

Description

ALARM 1 IN

13

Ground or Open (selectable by JP2) is Ch 1 alarm

ALARM 2 IN

14

Ground or Open (selectable by JP2) is Ch 2 alarm

REMOTE 1 IN

1

When in AUTO, momentary ground on this pin selects Ch 1

REMOTE 2 IN

2

When in AUTO, momentary ground on this pin selects Ch 2

REMOTE RESET IN

4

When in LATCH mode, ground resets switch to Ch 1

MANUAL INDICATION

8

*Open collector output (< 5

) to gnd when in Manual mode. 

SWITCH 1 MON

11

**Relay closure to J7 pin 6 (<5

) when selected RF is channel 1 RF.. 

SWITCH 2 MON

12

**Relay closure to J7 pin 6 (<5

) when selected RF is channel 2 RF. 

SWITCH MON COMMON

6

Common pin for SWITCH 1, 2 MONITOR

REMOTE MON

9

*Open collector (< 5

) to gnd when in REMOTE mode

GROUND

    

3,7,10

Ground

NO CONNECTION

    

5

Not connected

 

*Max voltage able to be connected to this is +20 VDC @ 30ma 
**Max voltage to be connected to this is +30 VDC@ 100 ma

AC1, AC2 - POWER IN 

- Provides AC inputs for dual power supplies.

1582-70L Manual_A

               Page 5  

4/09/09

Содержание 1582-70L

Страница 1: ... herein are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 88...

Страница 2: ...chnologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All shipping c...

Страница 3: ...ching relays so if power is removed from the 1582 70L CH1 and CH2 RF will continue to go to the output selected prior to power loss and will remain there when power is applied assuming no change in alarm status from when power was lost The channels can be manually switched by the front panel Manual Select switch If operating in the ICS mode the last channel manually selected CH1 or CH2 will be the...

Страница 4: ...s CH1 ON LINE Turns green when Channel 1 is selected CH2 ON LINE Turns green when Channel 2 is selected MANUAL Turns red when the Manual Select switch manually selects channel 1 or 2 ALARM CH1 Turns red when Channel 1 alarm input is a closure or open selectable ALARM CH2 Turns red when Channel 2 alarm input is a closure or open selectable ALARM HISTORY 1 Turns red on Channel 1 alarm and stays red ...

Страница 5: ...2 is Ch 2 alarm REMOTE 1 IN 1 When in AUTO momentary ground on this pin selects Ch 1 REMOTE 2 IN 2 When in AUTO momentary ground on this pin selects Ch 2 REMOTE RESET IN 4 When in LATCH mode ground resets switch to Ch 1 MANUAL INDICATION 8 Open collector output 5Ω to gnd when in Manual mode SWITCH 1 MON 11 Relay closure to J7 pin 6 5Ω when selected RF is channel 1 RF SWITCH 2 MON 12 Relay closure ...

Страница 6: ...or open selectable ALARM HISTORY 1 Turns red on Channel 1 alarm and stays red until HISTORY RESET is pushed ALARM HISTORY 2 Turns red on Channel 2 alarm and stays red until HISTORY RESET is pushed POWER CH1 LED Turns green when power is applied to AC1 input on the rear panel POWER CH2 LED Turns green when power is applied to AC2 input on the rear panel REMOTE LED Turns amber when REMOTE control is...

Страница 7: ...channel 1 alarms the 1582 70 switches to channel 2 until the alarm on channel 1 clears and then the 1582 70 switches back to channel 1 automatically JP3 normally position dot JP4 CH2 alarm enable ignore 3 pin jumper Dotted position Failure in CH1 will cause the 1582 70 to switch to CH2 even if CH2 is in alarm LEDs will correctly show CH2 alarm status Non dotted position Failure in CH1 will cause t...

Страница 8: ...equipment rack c Connect RF to the BNC connectors J1 J3 J4 J6 d Connect to signals on the MONITORS AND CONTROLS connector J7 as desired see Figure 2 0 Table 2 0 e Connect power via two power cords f Manually switch between channels 1 and 2 and be sure switching occurs g Switch to AUTO Alarm channel 1 and note that automatic switching occurs Remove alarm to channel 1 and note that the output switch...

Страница 9: ... 2 X X X Disable Latch Power On Reset X X X X X X X ICS Reset Auto Latch Manual 1 1 2 X X X ON X X ICS Reset Auto Latch Manual 2 1 2 X X X X ON X ICS Reset Auto Latch Remote 1 1 2 X X X X X ON ICS Reset Auto Latch Remote 2 1 2 X X X X X X Remote Select 1 X X X X X X X Remote Select 2 X X X X X X X Manual Select 1 X X X X X X X Manual Select 2 X X X X X X X Remote Reset X X X X X X X Local Reset X ...

Страница 10: ... CH2 if CH1 alarms and CH2 is good Latches to CH2 Push Reset or ground Remote Reset pin to return to CH1 if it has no alarm or both CH1 and CH2 are in alarm Non dot JP1 JP4 Dot JP2 JP3 S4 ALL TO OFF 3 Minimum Auto switching Initial Channel Select ICS Mode Switch stays on channel last selected by Manual or Remote selection after return to Auto if both channel alarms are clear or both channels are i...

Страница 11: ... is alarmed AND 2 is not alarmed In this case the Auto Latch U4 will be set to select CH2 A logic Low on the output of U4B pin 6 1 is not alarmed AND 2 is alarmed In this case the Auto Latch U4 will be set to select A If both alarm inputs are alarmed or both alarm inputs are not alarmed the Auto Latch will not be affected The output of the Auto Latch U4 pin 6 determines which RF source will be sel...

Страница 12: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1582 70L Manual Rev A Page 3 4 09 09 ...

Отзывы: