background image

 

 

Manual XM3 Remote Programmer: Version 4.1 

71 

8.2 

       - Set Anti-Pass back Time 

The Anti-Pass back Time is the period of time a user tag will be disabled 
when the Anti-Pass back feature is enabled. 

Format  

seconds

 

Min. value  

1

 

Max. value 

255

 

Default value 

0

 

 

Step

Action 

Result 

Present Remote Programmer 

Program mode entered 

Activate “Anti-Pass back Time”-
mode 

 

 

 

“Anti-Pass back Time”-mode is 
entered 

 

Set Anti-Pass back time 

 

 

XM3 resumes normal 
operation 

 

8.3 

     - Re-enable Users 

This function enables all users that are currently disabled as a result of the 
Anti-pass back feature. 

 

Step

Action 

Result 

Present Remote Programmer 

Program mode entered 

2 Re-enable 

users 

 

 

 

XM3 resumes normal 
operation 

Содержание XM3 MICROPROXS

Страница 1: ...MANUAL Remote Programmer XM3...

Страница 2: ......

Страница 3: ...grammer Version 4 1 3 Conditions Transactions deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel The Netherlands Registration num...

Страница 4: ...ator 18 2 6 XM3 Sleep modes 19 2 7 Tag Level Overview 20 3 Sleep mode 21 3 1 1 Show current XM3 level 21 3 1 2 Set new level prior to entering Sleep mode 21 3 2 Access 22 3 3 Add tags by number 23 3 4...

Страница 5: ...1 2 Public option 46 5 1 3 Egress option 46 5 1 4 Display Installer options 47 5 1 5 Set Installer options 48 5 2 Set Lock type 49 5 2 1 Set Lock type Normally Open 49 5 2 2 Set Lock type Normally Cl...

Страница 6: ...ration 66 7 2 3 Status 66 7 2 4 Display Event Log options 67 7 2 5 Set Event Log Options 68 7 3 Erase Event Log 69 8 Anti Pass back 70 8 1 1 Set Anti Pass back mode 70 8 2 Set Anti Pass back Time 71 8...

Страница 7: ...Manual XM3 Remote Programmer Version 4 1 7 11 Miscellaneous functions 83 11 1 Show Operational level 83 11 2 Show Remote Programmer level 84 11 3 XM3 Reset 85 11 4 Erase memory 86...

Страница 8: ...product In the interest of improvement specifications of the XM3 may vary slightly due to updates being made Detailed specifications of updates will be made available to be incorporated in the OEM s m...

Страница 9: ...umbers added to the XM3 meaning that they are read and inserted into the internal memory of the XM3 before they can be used Once added the tag number will be held in memory until it is voided erased M...

Страница 10: ...port for remote programmers Support for master cards 1 4 XM3 Single Door The XM3 can also be supplied as XM3 Single Door This XM3 Single Door contains most of the features mentioned above but with the...

Страница 11: ...bit H10302 H10304 HID Corporate 1000 Cross Point EM Mifare EM4001 and EM 4102 Mifare Standard Cross Point Table 1 Table 2 shows the various XM3 tag levels associated with the tag types Tag level Tag...

Страница 12: ...rded as a Master that has a more extensive repertoire and is equipped with a numeric keyboard When presented to the XM3 a unique code also engraved as a number on the outside is transmitted in a simil...

Страница 13: ...ramming caused an error the system can be bypassed i e power off the system hold the programmer known or unknown in the field while powering on The XM3 will go in Program mode Make sure that when doin...

Страница 14: ...ll control if the XM3 is in Installer mode and limited control over User settings when the XM3 is in User mode A User programmer has full control over User related settings if the XM3 is in User mode...

Страница 15: ...es No Yes Void tags by number Yes Yes Yes Set various User options Yes Yes Yes Set Open time Yes Yes Yes Set Close time Yes Yes Yes Add Night time master Yes No Yes Add Add Master Yes No Yes Add Void...

Страница 16: ...No Switch to RS 485 mode Yes No No Set XM3 address Yes No No Add a Pin Keypad Yes No No Set various Pin Keypad options Yes No No Set Event Log mode Yes No No Set Event Log options Yes No No Erase all...

Страница 17: ...es Add Unlock master Yes No Yes Re enable users in Anti passback mode Yes Yes Yes Switch Software Configuration Yes Yes Yes Show Operational level Yes Yes Yes Show Remote Programmer level Yes Yes Yes...

Страница 18: ...6 red LED 7 red Read indicator Access and Unlock mode Closed mode Night time mode Add mode Void mode Program mode Table 4 2 5 XM3 Sound Indicator In addition to the LED display the XM3 provides feedb...

Страница 19: ...status A Remote Programmer must be presented to wake the XM3 up This Remote Programmer if not yet known to the XM3 will be declared a Installer Programmer After presenting the Remote Programmer the XM...

Страница 20: ...ag levels are used to assign specific functionality to a tag Table 8 shows the various tag levels Tag level Tag type 11 Installer Programmer 10 User Programmer Program Master 9 Void Master 8 Add Maste...

Страница 21: ...Programmers that are added later See chapter 2 6 for more details on the Sleep modes 3 1 1 Show current XM3 level Present the Remote Programmer Press The XM3 LEDs show the current XM3 level see chapte...

Страница 22: ...emote Programmer can obtain access there is no need for a separate user tag Step Action Result 1 Present Remote Programmer Program mode entered 2 Relay is activated After the Open time period has pass...

Страница 23: ...ause the person carrying it is not present it can still be added by entering its Add level and number with a legitimate Remote Programmer as described below Step Action Result 1 Present Remote Program...

Страница 24: ...ote Programmer can be used to obtain access while switching the XM3 to Access mode just like a Night time Master Activate Night time mode using any Remote Programmer Step Action Result 1 Present Remot...

Страница 25: ...emote Programmer new tags can be added when they are presented Tags added in this way will be defined as Daytime only tags normal users Step Action Result 1 Present Remote Programmer Program mode ente...

Страница 26: ...ed from memory After this step which clears the memory space they occupied they will be regarded as unknown by the XM3 Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Vo...

Страница 27: ...as 4 digit decimal numbers representing a 24 hour time stamp in the hhmm format e g 2359 23 59 Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Set Clock mode Set Clock m...

Страница 28: ...ted access both in Access mode and in Night time mode These Special User tags can be added directly without setting Night time mode first Step Action Result 1 Present Remote Programmer Program mode en...

Страница 29: ...nly outside normal office hours and during holidays when the XM3 would be set to Night time mode In such cases the Night time status functions as a discriminative time zoning system Step Action Result...

Страница 30: ...r must be known For this reason it is important to keep records of all added tags Masters and Remote Programmers Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Void mod...

Страница 31: ...memory even if they have higher levels are prevented from entering Program mode By default the Protect option is off Protect can be bypassed only when the Programmer is presented in the RF field while...

Страница 32: ...is activated XM3 LEDs Activated User option LED 1 LED 2 ON LED 3 LED 4 ON LED 5 LED 6 LED 7 Protect option Read Indicator on LED 1 Table 9 Follow the next procedure to display the activated user opti...

Страница 33: ...ined the individual values must be added For example when setting both Protect and Read indication enter 5 1 4 Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate User Optio...

Страница 34: ...of seconds called the Open Time out For testing purposes 4 seconds for a normal door and 20 seconds for a gate are recommended Format seconds Min value 1 Max value 255 Default value 3 Step Action Resu...

Страница 35: ...default the Close Time out is set to 0 which means the Close Time out option is disabled Any other value will activate the Close Time out option and requires I O1 to be connected to ground through a d...

Страница 36: ...his mode is called the Night time mode This mode can be switched on and off by a Night time Master tag or alternatively with a Remote Programmer Step Action Result 1 Present Remote Programmer Program...

Страница 37: ...e tag privileged to perform this function For instance a particular person or a specific group of persons authorized to work in certain rooms or areas where XM3 units are applied might carry a separat...

Страница 38: ...e tag privileged to perform this function For instance a particular person or a specific group of persons authorized to work in certain rooms or areas where XM3 units are applied might carry a separat...

Страница 39: ...ogrammer mode using the original Remote Programmer a new Remote Programmer can be added by presentation Step Action Result 1 Present the original Remote Programmer Program mode entered 2 Activate Copy...

Страница 40: ...re set value the XM3 generates an alarm and resumes normal operation Format seconds Min value 5 Max value 255 Default value 30 Step Action Result 1 Present the original Remote Programmer Program mode...

Страница 41: ...e Change code A PIN Code Change code can has to be used by a user to change his personal PIN code on the PIN keypad For security reasons the user needs to know the PIN Code Change code to be able to c...

Страница 42: ...nt the Remote Programmer Program mode entered 2 Activate Pin Access code mode Pin Access code mode is entered 3 Set Pin Access code XM3 resumes normal operation 4 9 3 Set Alarm Code A special Alarm Co...

Страница 43: ...nt alarm is activated LED2 will keep blinking during the Inactivity Timer period I O3 is activated 3 After the Inactivity Timer has ended the XM3 will resume normal operation The silent alarm can be d...

Страница 44: ...r can be used to change the User level Access code when the end user has forgotten the User level Access code and therefore can not access the XM3 through the software anymore Format digit Min value 0...

Страница 45: ...s is not memorized in EPROM so after a power failure or a deliberate power off the XM3 always resets to the latest status By connecting I O4 to an external relay circuit an external device can be acti...

Страница 46: ...safe deposits parking lots and front doors of large hotels public institutions or companies etc 5 1 3 Egress option Allows the connection of a push button mounted inside a separate room This push butt...

Страница 47: ...vated XM3 LEDs Activated Installer option LED 1 LED 2 ON LED 3 ON LED 4 ON LED 5 LED 6 LED 7 Private option Public option Egress ption Table 10 Follow the next procedure to display the activated Insta...

Страница 48: ...ned the individual values must be added For example when setting both Private and Egress options enter 5 1 4 Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Installer Op...

Страница 49: ...s directly connected to the XM3 The coded signal is used to trigger an external relay for example an external relay on a Connection Unit Cross Point article XMCU3 A The external relay offers higher se...

Страница 50: ...0 Manual XM3 Remote Programmer Version 4 1 5 2 3 Set Lock type Coded Signal Step Action Result 1 Present Remote Programmer Program mode entered 2 Set Lock type Coded Signal XM3 resumes normal operatio...

Страница 51: ...be used to change the Installer level Access code when the end user has forgotten the Installer level Access code and therefore can not access the XM3 through the software anymore Format digit Min val...

Страница 52: ...or pulsing 5 4 2 Redirect Tamper alarm output This option can be used to separate the tamper alarm and the forced entry alarm Default they are both available on I O3 With this option set the tamper a...

Страница 53: ...option LED 1 LED 2 LED 3 LED 4 ON LED 5 ON LED 6 ON LED 7 ON Alarm tone option Redirect Tamper alarm option Tamper alarm enabled option Tamper alarm disabled option Table 11 Follow the next procedure...

Страница 54: ...e to be combined the individual values must be added For example when setting both Tamper alarm redirect and Tamper alarm on options enter 24 8 16 Step Action Result 1 Present Remote Programmer Progra...

Страница 55: ...very XM3 option there is a file in the file system Table 12 shows an overview of the available File System configurations and their options File System Users PIN codes Names Events 0 5000 0 0 0 1 3700...

Страница 56: ...e file system will result in a loss of all users and events currently stored in the XM3 Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Set File System mode File System...

Страница 57: ...internal memory of the XM3 is not used anymore The controller stores all user related information and will decide whether the presented user tag gains access or not The available XM3 on line interface...

Страница 58: ...er programmer at Installer level Format digit Min value 1 Max value 255 Default value see XM3 label Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Set Address mode Set...

Страница 59: ...with the PIN code option 6 1 Add a PIN Keypad Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Add PIN Keypad mode Add PIN Keypad mode is entered 3 Present new PIN Keypa...

Страница 60: ...e After the PIN Keypad has been added to the XM3 memory the PIN code option has to be enabled forcing all users to type a PIN code after presenting their tags 6 2 3 Use PIN Keypad as User Programmer T...

Страница 61: ...taller option LED 1 LED 2 ON LED 3 ON LED 4 ON LED 5 ON LED 6 LED 7 Alarm Notification mode Enable PIN code PIN Keypad as User Prog PIN at night only Table 13 Follow the next procedure to display the...

Страница 62: ...options are to be combined the individual values must be added For example when setting both Alarm Notification mode and Enable PIN code options enter 3 1 2 Step Action Result 1 Present Remote Progra...

Страница 63: ...user will be prompted to define his her PIN code The PIN code must consist of 4 digits and can only be entered through the PIN Keypad not by using a Remote Programmer Step Action Result 1 Present Use...

Страница 64: ...pletely from the XM3 s memory and added again to be able to define a new PIN code Note Before entering the Pin code Change code press the first Step Action Result 1 Present User tag which PIN code nee...

Страница 65: ...Note Events can only be retrieved and viewed by connecting the XM3 to a PC that runs the XM3 Manage software 7 1 Enable Disable Event Logging Option Value Event logging disabled 0 Event logging enabl...

Страница 66: ...ted A user logged on via the user interface XM3 Manage 7 2 2 Configuration Configuration related events like A system area parameter was changed A user was added to voided from the XM3 database A user...

Страница 67: ...2 ON LED 3 ON LED 4 ON LED 5 LED 6 LED 7 Security related events Configuration related events Status related events Table 14 Follow the next procedure to display the activated Event Log options Step A...

Страница 68: ...o be combined the individual values must be added For example when enabling both Security and Configuration events enter 3 1 2 Step Action Result 1 Present Remote Programmer Program mode entered 2 Act...

Страница 69: ...se Event Log All events can be manually erased by using the Remote Programmer Step Action Result 1 Present Remote Programmer Program mode entered 2 Erase all events XM3 resumes normal operation Note T...

Страница 70: ...ining access After the anti pass back time has elapsed the user can gain access again by presenting his her tag 8 1 1 Set Anti Pass back mode When the Anti Pass back feature is disabled a user can gai...

Страница 71: ...alue 0 Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Anti Pass back Time mode Anti Pass back Time mode is entered 3 Set Anti Pass back time XM3 resumes normal operatio...

Страница 72: ...time zone for the complete 24 hours of that day For instance when the time zones are disabled for Saturday and Sunday the Xm3 will go into night time zone on Friday night and will switch to day time...

Страница 73: ...mat hours Min value 00 Max value 24 Default value 00 Format minutes Min value 00 Max value 60 Default value 00 The time markers indicate the first minute during which access in the respective time zon...

Страница 74: ...arker mode Night to Day marker mode is entered 3 Set Night to Day marker set hhmm time value XM3 resumes normal operation 9 1 2 Set Day to Night marker Step Action Result 1 Present Remote Programmer P...

Страница 75: ...M3 LEDs Activated weekday LED 1 ON LED 2 ON LED 3 ON LED 4 ON LED 5 ON LED 6 ON LED 7 ON Sunday Monday Tuesday Wednesday Thursday Friday Saturday Table 15 Follow the next procedure to display the acti...

Страница 76: ...on will deactivate the selected weekday setting and vice versa Default value All weekdays Option Value Sunday 0 Monday 1 Tuesday 2 Wednesday 3 Thursday 4 Friday 5 Saturday 6 Step Action Result 1 Prese...

Страница 77: ...t to enter the building need to present their tag to gain access XM3 behavior in Unlock mode LED 2 green will be continuously lit All valid Remote Programmers and Master tags will keep their functiona...

Страница 78: ...359 23 59h Format hours Min value 00 Max value 24 Default value 00 Format minutes Min value 00 Max value 60 Default value 00 The time markers indicate the first minute during which access in the respe...

Страница 79: ...r mode Lock to Unlock marker mode is entered 3 Set Lock to Unlock marker set hhmm time value XM3 resumes normal operation 10 1 2 Set Unlock to Lock marker Step Action Result 1 Present Remote Programme...

Страница 80: ...XM3 LEDs Activated weekday LED 1 ON LED 2 ON LED 3 ON LED 4 ON LED 5 ON LED 6 ON LED 7 ON Sunday Monday Tuesday Wednesday Thursday Friday Saturday Table 16 Follow the next procedure to display the act...

Страница 81: ...tion will deactivate the selected weekday setting and vice versa Default value All weekdays Option Value Sunday 0 Monday 1 Tuesday 2 Wednesday 3 Thursday 4 Friday 5 Saturday 6 Step Action Result 1 Pre...

Страница 82: ...this tag the Lock Unlock feature will be enabled disabled Step Action Result 1 Present Remote Programmer Program mode entered 2 Activate Add Unlock Master mode Add Unlock Master mode is entered 3 Pres...

Страница 83: ...Operational level is displayed on the XM3 LEDs XM3 LEDs Operational level LED 1 LED 2 ON LED 3 ON LED 4 LED 5 LED 6 LED 7 User level Installer level Table 17 Step Action Result 1 Present Remote Progra...

Страница 84: ...isplayed on the XM3 LEDs XM3 LEDs Remote Programmer level LED 1 LED 2 ON LED 3 ON LED 4 LED 5 LED 6 LED 7 User programmer Installer programmer Table 18 Step Action Result 1 Present Remote Programmer P...

Страница 85: ...ion present in the memory of the XM3 will not be lost and parameter settings will not be restored to default values Temporary settings will be restored to previous settings Step Action Result 1 Presen...

Страница 86: ...ich group s must be erased a so called erase level must be entered All tags and Remote Programmers at or below this level will be erased See Table 8 for an overview of the tag levels Step Action Resul...

Отзывы: