2.6
XM3 Sleep modes
As indicated before, the XM3 can be set to two different operational levels,
Installer level and User level.
The XM3 can also be set to sleep mode in these two levels (sometimes by
factory default. See Table 6 and Table 7 for instructions on how to wake the
XM3 up from the various sleep modes.
Installer level Sleep mode
LEDs status
A Remote Programmer must be presented to wake the
XM3 up.
This Remote Programmer (if not yet known to the XM3)
will be declared a Installer Programmer.
After presenting the Remote Programmer the XM3 will
switch to Access mode.
Table 6
User level Sleep mode
LEDs status
A Remote Programmer or tag must be presented to wake
the XM3 up.
The Remote Programmer (if not yet known to the XM3)
will be declared a User Programmer.
The tag (if not yet known to the XM3) will be declared as
a Program Master.
After presenting the Remote Programmer or the tag the
XM3 will switch to Access mode.