3.21
Pegasus BT-POM 1212 - Rev 3
Section 3
Chemical Mixing
Step 3
Engage the PTO to start the main spray
pump operating at low revs.
DO NOT OPERATE AT FULL REVS.
If you are operating a hydraulic drive on
the pump, turn down the hydraulic flow to
slow the pump down temporarily.
Do not operate the pump at full speed
when filling with the Enviro-transfer,
otherwise damage to plumbing may
result.
CAUTION
Enviro-transfer Kit
The Enviro-transfer kit is a volumetric
filling system designed to transfer
chemicals directly from Envirodrums into
the Chem-e-flush mixer/induction unit on
the Pegasus.
If using a closed centre system hydraulic
pump as explained on page 2.15, you can
OPEN the control valve to slow down the
enviro-transfer speed.
Remember to close the valve and check
the pump speed after transfer is complete.
Step 1
Unclip the Micromatic fitting from the
docking fitting on the sprayer and clip
it into the Envirodrum containing the
chemical you intend to use.
Step 2
Turn the rotary selector on the main
control panel to “Chem Hopper”.
Ensure the Chem-e-flush is empty of any
liquid or residue before progressing.
The Chem-e-flush can be left in the “up”
position during the following process. It
is not necessary to lower the drop-leg.
The operator must not leave the Enviro-
transfer kit unattended while filling.
Over-filling and chemical spillage could
result if the unit is unattended during
the transfer process.
The system is only suitable for liquid
transfer.
WARNING
Unclip the Micromatic fitting from its docking point.
Turn the rotary selector to “Chem Hopper”.
Clip the Micromatic fitting finto the Envirodrum.
Содержание PEGASUS 4000
Страница 26: ......
Страница 69: ...5 3 Pegasus BT POM 1212 Rev 3 Section 5 Grease Point Diagrams Boom Grease Points Chassis PTO Grease Points ...
Страница 78: ...5 12 Pegasus BT POM 1212 Rev 3 ...
Страница 101: ...7 13 Pegasus BT POM 1212 Rev 3 Section 7 PLEASE TURN TO THE NEXT PAGE ...
Страница 110: ...7 22 Pegasus BT POM 1212 Rev 3 Assembly Drawings Parts Listings Chassis Tank Wheels ...
Страница 121: ...7 33 Pegasus BT POM 1212 Rev 3 Section 7 Plumbing Diagram AR180 ...
Страница 122: ...7 34 Pegasus BT POM 1212 Rev 3 Assembly Drawings Parts Listings Plumbing Diagram AR250 280 ...
Страница 138: ...7 50 Pegasus BT POM 1212 Rev 3 Assembly Drawings Parts Listings GBCOMPL 24 28CA Centre Section 24 28m ...
Страница 146: ...7 58 Pegasus BT POM 1212 Rev 3 Assembly Drawings Parts Listings GBCOMPL 285 LHorRH BoomNonGvar28m 7 8 5 8 C ...
Страница 152: ...7 64 Pegasus BT POM 1212 Rev 3 Assembly Drawings Parts Listings GBCOMPL 30C Centre Section 30m 8 1 ...
Страница 158: ...7 70 Pegasus BT POM 1212 Rev 3 Assembly Drawings Parts Listings AB19100 AA 33 36m Centre Section Hanger V2 ...
Страница 165: ......
Страница 166: ......
Страница 167: ......