background image

Adapter Tau-PCI/32, User Manual

 

 

Copyright © 2004-2007 Cronyx

 

7

 

The transceiver provides exchange (reception/transmission) of information between 

the “logical channels” and RAM via the PCI bus. The logical channels of the transceiver 
are formed from the predefined E1 timeslots. Each timeslot can be "connected" to only 
one logical channel. This allows up to 32 logical channels to be obtained. The exchange 
of the data in the logical channel is a synchronous process that occurs at a speed 
dependent on the number of the connected timeslots (unbalanced as an option). For each 
logical channel, defined are a channel protocol (HDLC, transparent mode, etc.) and a 
specific reception and transmission order; each channel can be started and suspended 
independently of the others. 

The on/off CAS signaling maintenance block allows you to implement associated 

channel signaling processing adjusted for cross switching. The CAS maintenance block 
exchanges data with the transceiver using timeslot 16, and, on the other hand, interacts 
with the cross connector using a separate parallel data bus. The CAS maintenance block 
is not included in the Tau-PCI/32-Lite, because its functionality becomes redundant and 
unrequested with only one E1 interface available.  

The nonblocking cross-connector allows you to set an “incoming” source for each 

“outgoing” timeslot. This allows you to randomly switch and rearrange timeslots, provide 
digital loops etc. The cross switching matrix is updated at the E1 frame border. In 
addition to the data, the cross connector concurrently processes CAS signaling. 

The use of the CAS maintenance block simultaneously to the activation of signaling 

exchange at E1 interfaces produces full-value, three points cross switching of both 
timeslots and CAS signaling. 

An on/off switch of Sa-bits (Sa4 … Sa8) allows you to arrange 

reception/transmission of Sa-bit values and enable them to be exchanged between E1 
interfaces. The Sa-bit switch exchanges data with the transceiver via timeslot 0, and, on 
the other hand, interacts directly with the E1 interfaces. 

The on/off modules for supporting the unstructured mode for each E1 interface are 

balanced type and controlled independently. The “unstructured” mode means that the E1 
data flow does not have a frame structure according to ITU-T G.704, at the same time 
data is transmitted in a synchronous bit flow at 2048 Kbps, and the borders of the 
timeslots are not defined. Correspondingly, cross connector, CAS maintenance block and 
Sa-bit switch become useless. 

The activation of the unstructured mode at 2048 Kbps at one of the E1 interfaces (no 

bit rate slow-down, see below) results in the engagement of all the transceiver timeslots. 
The exchange of data with the other E1 interface and other functional blocks in the 
adapter becomes impossible.  Correspondingly, one logical channel for all timeslots must 
be activated in the transceiver. 

For compatibility with other equipment by Cronyx, the adapter supports scrambler 

and multiple bit rate slow-down modes (2x, 4x, 8x, 16x and 32x). Simultaneously, the 
physical data transmission rate always remains 2048 Kbps, only the useful transmission 
rate changes. 

Содержание Tau-PCI/32

Страница 1: ...opyright 2004 2007 Cronyx Version 1 3 June 2007 Tau PCI 32 Tau PCI 32 Lite Adapters for PCI bus One or two E1 PCM 30 interfaces built in cross connector up to 32 data links up to 2048 Kbps User Manual...

Страница 2: ...Options 4 Deliverables 5 E1 Line Protection 5 Interior Design of the Adapter 5 Adapter Installation 8 Adapter Check 9 Software Installation 9 Adapter Configuration in Linux 10 Adapter Configuration i...

Страница 3: ...r 64 Kbps unframed mode software selectable for each interface Generator Stability 50 ppm Line Coding AMI or HDB3 software selectable for each interface Line Impedance 120 Ohms twisted pair for coaxia...

Страница 4: ...ibrary DDK Driver Development Kit will be supplied to deliver required enhanced functionality Key Features Two E1 interfaces with high sensitivity receivers Up to 32 independent logical synchronous da...

Страница 5: ...ed breakdown voltage of about 7 5V and the tolerated pulse current of 200A and small self capacitance Interior Design of the Adapter Functionally the Tau PCI 32 adapter can be divided into six primary...

Страница 6: ...Tau PCI 32 Adapter User Manual 6 Copyright 2004 2007 Cronyx...

Страница 7: ...1 frame border In addition to the data the cross connector concurrently processes CAS signaling The use of the CAS maintenance block simultaneously to the activation of signaling exchange at E1 interf...

Страница 8: ...ck can be used as such a source If clock signals from the external source are lost the adapter always automatically switches to the internal clock Only the basic operation modes needed to construct pa...

Страница 9: ...interface models the same sequence can be performed to test the second E1 1 interface If the equipment has been connected correctly and is functional each test must yield no errors with allowance for...

Страница 10: ...or the channels during the OS startup by using the examples supplied in the distribution kit To get brief help about the sconfig utility you can run the following command sconfig help A full descripti...

Страница 11: ...Adapter Tau PCI 32 User Manual Copyright 2004 2007 Cronyx 11 List of E1 PCM 30 Interface Signals Pin No in DB 15 Connector Signal Name 1 XMT a 2 GND 3 RCV b 9 XMT b 10 GND 11 RCV a...

Страница 12: ...7 71 Fax 7 495 742 17 73 E mail info cronyx ru Prices http www cronyx ru price Please send all requests and remarks regarding this manual and the use of the software at info cronyx ru ly cronyx ru Cro...

Отзывы: