Adapter Check 

The adapter delivery set includes two 3.5” floppies or a CD-ROM. If floppy disks are 

included, boot up the computer using the “Diagnostic Boot” floppy, otherwise boot up 
from the CD-ROM. 

After the boot, a diagnostic application that will start automatically will search and 

perform basic testing of the internal circuits (bus test) of the installed adapters. Then, you 
choose the adapter that needs testing. 

The diagnostic application allows you to run various tests, which involve the use of 

appropriate external equipment and/or E1 interface loopbacks. 

For most cases, the following steps will be sufficient to check the availability of the 

adapter: 

ƒ

 

Access the Test menu and run the General Test command; 

For complete check of the protection circuits and E1 interface health: 

ƒ

 

Access the Cross Connector menu and run the Enable E1/

0

 command; 

ƒ

 

Connect the external loopback (supplied) to the E1/

0

 interface; 

ƒ

 

Access the Test menu and run the Receive/Transmit command; 

For dual-interface models, the same sequence can be performed to test the second 

E1/

1

 interface. 

If the equipment has been connected correctly and is functional, each test must yield 

no errors (with allowance for several start errors due to synchronization adjustment). 

For instructions that are more detailed please refer to the support service.  

Software Installation 

The adapter delivery set includes two 3.5” floppy disks or CD-ROM. If floppy disks 

are included, one contains a testing application and is a boot floppy (labeled "Diagnostic 
Boot"), and the other contains drivers for the supported operating systems. 

If floppy disks are included, the drivers for FreeBSD and Linux can be found on the 

second floppy. Drivers for any version Windows are not available. The readme.txt file 
contains a full list of the drivers. You can read the floppy files using the "mread" utility 
("mtools" package). To unpack, use "tar" utility. For example: 

mread a:

 

clinux445.tgz 

tar xvzf clinux445.tgz 

After unpacking, install the driver according to the instructions contained in the 

readme.txt file. For the latest drivers and other accompanying software, you should visit 
the Cronyx website. Before you install the software, please read all of the attached 
documentation carefully. 

Содержание Tau-PCI/32

Страница 1: ...opyright 2004 2007 Cronyx Version 1 3 June 2007 Tau PCI 32 Tau PCI 32 Lite Adapters for PCI bus One or two E1 PCM 30 interfaces built in cross connector up to 32 data links up to 2048 Kbps User Manual...

Страница 2: ...Options 4 Deliverables 5 E1 Line Protection 5 Interior Design of the Adapter 5 Adapter Installation 8 Adapter Check 9 Software Installation 9 Adapter Configuration in Linux 10 Adapter Configuration i...

Страница 3: ...r 64 Kbps unframed mode software selectable for each interface Generator Stability 50 ppm Line Coding AMI or HDB3 software selectable for each interface Line Impedance 120 Ohms twisted pair for coaxia...

Страница 4: ...ibrary DDK Driver Development Kit will be supplied to deliver required enhanced functionality Key Features Two E1 interfaces with high sensitivity receivers Up to 32 independent logical synchronous da...

Страница 5: ...ed breakdown voltage of about 7 5V and the tolerated pulse current of 200A and small self capacitance Interior Design of the Adapter Functionally the Tau PCI 32 adapter can be divided into six primary...

Страница 6: ...Tau PCI 32 Adapter User Manual 6 Copyright 2004 2007 Cronyx...

Страница 7: ...1 frame border In addition to the data the cross connector concurrently processes CAS signaling The use of the CAS maintenance block simultaneously to the activation of signaling exchange at E1 interf...

Страница 8: ...ck can be used as such a source If clock signals from the external source are lost the adapter always automatically switches to the internal clock Only the basic operation modes needed to construct pa...

Страница 9: ...interface models the same sequence can be performed to test the second E1 1 interface If the equipment has been connected correctly and is functional each test must yield no errors with allowance for...

Страница 10: ...or the channels during the OS startup by using the examples supplied in the distribution kit To get brief help about the sconfig utility you can run the following command sconfig help A full descripti...

Страница 11: ...Adapter Tau PCI 32 User Manual Copyright 2004 2007 Cronyx 11 List of E1 PCM 30 Interface Signals Pin No in DB 15 Connector Signal Name 1 XMT a 2 GND 3 RCV b 9 XMT b 10 GND 11 RCV a...

Страница 12: ...7 71 Fax 7 495 742 17 73 E mail info cronyx ru Prices http www cronyx ru price Please send all requests and remarks regarding this manual and the use of the software at info cronyx ru ly cronyx ru Cro...

Отзывы: