WARRANTY

CROMTECH™and CROMMELINS™ are a registered trademark of The 

Crommelin Group. Crommelins warrants their goods against defects in 

materials and workmanship under normal use and service.

The Crommelin Group warranty does not cover fair wear commensurate 

with the age of the product, any damage caused by accident, abuse, 

misuse, neglect or failure to observe proper operating instructions or 

proper machinery maintenance as described in the instruction manual.

It is the owner’s responsibility to regularly maintain a product in 

accordance with the owner’s manual and only use the equipment for its 

designed purpose.

Our goods come with guarantees that cannot be excluded under the 

Australian Consumer Law. You are entitled to a replacement or refund 

for a major failure and for compensation for any other reasonably 

foreseeable loss or damage. You are also entitled to have goods repaired 

or replaced if the goods fail to be of acceptable quality and the failure 

does not amount to a major failure.

CONSUMER ADVICE

Any claim under these warranties must be made in the warranty period 

from the date of purchase of the product.

There are over 185 national authorised service/repair agents available, 

visit www.crommelins.com.au for their details and locations.

To make a claim under the warranty, you must return the product  

(with proof of purchase) to the closest warranty agent or to the place of 

purchase.

Where a failure does not amount to a major failure, Crommelins 

Machinery is entitled to choose between providing you with a repair, 

replacement or refund. To obtain compensation, you would need to 

provide documentary evidence of the loss or damage suffered, and 

documentary evidence that such loss or damage was a reasonably 

foreseeable consequence of a failure by The Crommelins Group to comply 

with a consumer guarantee under the Australian Consumer Law.

Crommelins Operations Pty Ltd trading as The Crommelin Group, 

Crommelins Australia and Crommelins Machinery

THE CROMMELIN GROUP:

Phone (08) 9350 5588   Fax (08) 9451 6381 

[email protected]

www.crommelins.com.au

PO Box 352, BENTLEY WA 6982

ABN 11 008 889 656

Pg. 4

Cromtech Diesel 6000W Generator Manual April 2020.indd   4

Cromtech Diesel 6000W Generator Manual April 2020.indd   4

21/4/20   7:25 pm

21/4/20   7:25 pm

Содержание TG6000DVE

Страница 1: ...CH DIESEL GENERATOR OPERATION MANUAL DIESEL 6000W GENERATOR Cromtech Diesel 6000W Generator Manual April 2020 indd 1 Cromtech Diesel 6000W Generator Manual April 2020 indd 1 21 4 20 7 25 pm 21 4 20 7...

Страница 2: ...rdous situation which if not strictly complied with will result in substantial property damage serious injury or DEATH WARNING Indicates a hazardous situation which if not strictly complied with may r...

Страница 3: ...15 Pre start Instructions 16 Starting the Generator 16 Electric start 16 Recoil start manual start 17 Running the generator 17 During operation 17 Stopping the generator 18 AC application 18 Generator...

Страница 4: ...ese warranties must be made in the warranty period from the date of purchase of the product There are over 185 national authorised service repair agents available visit www crommelins com au for their...

Страница 5: ...umer use only This generator is not designed for permanent application WARNING Before each use check for loose or damaged parts signs of oil or fuel leaks and any other condition that may affect prope...

Страница 6: ...colourless poison gas Using engine indoors CAN KILL YOU NEVER use generator inside any building or any kind of enclosure EVEN IF doors and windows are open Place the generator in a well ventilated ar...

Страница 7: ...ce Avoid spilled battery acid If contact with skin is made wash immediately with clean water WARNING ELECTRICAL SHOCK This generator produces powerful voltage and the electricity CAN KILL YOU To reduc...

Страница 8: ...eset switch s RCD Breaker 2x 15 Amp Outlets Earth screw Air cleaner Recoil start Ignition switch VHT Meter Outlets Circuit breakers Grounding screw Rubber mounts Alternator Oil drain plug Oil filler c...

Страница 9: ...95db Weight kg 103 5kg Packaging LxWxH 800x550x640mm FEATURES 2x Outlets single phase 15amp IP66 rate RCD Protection AC Overload protection VHT Meter Volts Hertz Time Diesel powered Electric start and...

Страница 10: ...d of enclosure EVEN IF doors and windows are open Place the generator in a well ventilated area and carefully consider wind and air currents when positioning generator 2 OPERATING CONDITION Check for...

Страница 11: ...dipstick 3 If lower fill to the upper limit marked with H of the dipstick with the recommended oil Reinsert and fully tighten the dipstick WARNING Oil is a major factor affecting performance and servi...

Страница 12: ...dling diesel fuel Fill fuel tank outdoors and in a well ventilated area with the engine stopped Always wipe off spilled fuel and wait until the fuel has dried before starting the engine DO NOT operate...

Страница 13: ...ith an RCD Circuit Breaker ALWAYS test RCD switch before every use CAUTION Do not use any appliance with a damaged cord or switch NOTE Allow the engine to stabilise and warm up for a few minutes after...

Страница 14: ...WARNING DO NOT overload the generator Exceeding the capacity of generator can damage the generator and or electrical devices connected to it You must make sure your generator can supply the rated run...

Страница 15: ...can start at the same time total surge watts can be estimated by adding only the electrical device s with the highest additional surge watts to the total rated watts WATTAGE REFERENCE GUIDE ONLY ELEC...

Страница 16: ...F position 3 Bleed the fuel line by pulling the recoil starter to start the flow of fuel 4 Continue until there is no air bubbles coming out and the fuel is flowing freely 5 Tighten fuel connection nu...

Страница 17: ...ull out the recoil start handle and prepare to start the generator 6 Pull the rope to the point where resistance is felt Return the recoil handle to the initial position 7 Grip the recoil handle firml...

Страница 18: ...the engine with the decompression lever AC APPLICATION NOTICE Do not run generator for extended periods with no load or minimal load e g when charging batteries or powering low wattage equipment such...

Страница 19: ...service intervals indicated in the chart below Service your generator more frequently when operating in adverse conditions Contact your local service agent for parts or engine maintenance needs See m...

Страница 20: ...t back in the air cleaner and reattach the cover Tighten wing nut CHECK CHANGE FUEL FILTER WARNING Change filter regularly to insure maximum engine output CLEAN FILTER Every 6 months or 300 hours REPL...

Страница 21: ...NING A licensed electrician should always carry out electrical maintenance work Cromtech Diesel 6000W Generator Manual April 2020 indd 21 Cromtech Diesel 6000W Generator Manual April 2020 indd 21 21 4...

Страница 22: ...ths or longer i Clean the generator according to the instructions in the maintenance section Page 27 ii Run the generator for 3 minutes and stop it iii Drain old oil and replace with fresh oil iv Turn...

Страница 23: ...tlet 1 Check RCD breaker 2 There is not power to outlet 2 Check AC overload 3 The rated speed of the generator can not be reached 3 Consult you local service agent for adjustments 4 Inadequate power c...

Страница 24: ...H DIESEL GENERATOR OPERATION MANUAL DIESEL 6000W GENERATOR Cromtech Diesel 6000W Generator Manual April 2020 indd 24 Cromtech Diesel 6000W Generator Manual April 2020 indd 24 21 4 20 7 25 pm 21 4 20 7...

Отзывы: