background image

GLASS  DRILL InStRuctIon  MAnuAL

GLASS-cHEK PRo oPERAtInG MAnuAL

crlaurence.com

c.R. Laurence co., Inc.    

    2503 E. Vernon Ave., Los Angeles, cA 90058     

    1.800.421.6144      

    crlaurence.com

SEPtEMBER 2020

AVDB3409_09/20

Glass Thickness Meter and  

Low-E Detector with Laminates

Cat. No. GC 3001

Содержание CRL GLASS-CHECK PRO GC3001

Страница 1: ...SS CHEK PRO OPERATING MANUAL crlaurence com C R Laurence Co Inc 2503 E Vernon Ave Los Angeles CA 90058 1 800 421 6144 crlaurence com SEPTEMBER 2020 AVDB3409_09 20 Glass Thickness Meter and Low E Detec...

Страница 2: ...nd warranty information Table of Contents Page 1 Introduction and Table of Contents Page 2 Meter Layout Results Screen Explanation MENU Options Page 3 Navigating the MENU Unit of Measure Results Scree...

Страница 3: ...erating mode for your application Choosing the wrong mode can result In Incorrect measurement results or no results at all Remember If you change the operating mode It will stay In that mode for all f...

Страница 4: ...ter the MENU system any time the meter is powered on by pressing and holding one of the ARROW buttons Please note that you may need to hold the ARROW button down for several seconds before entering th...

Страница 5: ...on of this feature see the Measurement Examples section When you exit the Display Units menu the meter will show an example of what the measurement results screen will look like according to your sele...

Страница 6: ...the ARROW keys to change the time and then press ain MENU PLEASE NOTE If you would prefer that the change the Result Screen times to the maximum value of me each screen is displayed allowing you to a...

Страница 7: ...stop navigating the menu and allow the meter to automatically power down The meter will automatically shut off after 1 to 2 minutes of inactivity When the meter powers back up it will display the prev...

Страница 8: ...n while taking a measurement Place your index finger next to the button as shown at left Proper Operation of the Glass Chek ELITE Page 6 Place the meter at the bottom center of the window to be tested...

Страница 9: ...is on surface 3 Please note there are times where the meter will not specifically designate surface 3 and may show the result as Surface 3 or 4 This means that the meter is only indicating the coatin...

Страница 10: ...format the measurement will alternate the following three messages Resulting Measurement Displays Due to the application and display format the measurement will alternate the following 2 messages Dis...

Страница 11: ...s lami 159 or 5 32 On screens 2 and 4 you will see that these two thickness values are denoted by the letter D D1 D2 Because the meter does not know which thickness value is the glass and which one co...

Страница 12: ...e material when taking measurements will result in the most accurate Low E measurements One additional note regarding Low E detection If your application contains more than one low e coating in the wi...

Страница 13: ...the window A convenient reference chart is included with the GC3001 meter that lists many of the common Low E coatings used in the USA Here are some examples Triple Pane Windows The GC3001 will specif...

Страница 14: ...will take to complete a measurement 2 If testing dark glass in a window try to test from the side of the window that contains the clear piece of glass 3 Always conduct your measurements in the BOTTOM...

Страница 15: ...error message will appear that recommends replacing the battery soon This gives the user plenty of warning that a battery replacement is needed soon but the meter will still function for a period aft...

Страница 16: ...meter will record accurate readings until the point the electronics reach the temperature below the operating range Depending on the degree of coldness this will allow for several readings to be taken...

Страница 17: ...hing the glass while taking measurements Placing your hand or any metallic object against the lite of glass you are testing may cause the Glass Chek ELITE to yield improper Low E results Remove your h...

Страница 18: ...space and the total IG thickness Depending on the thickness of the glass the maximum thickness range for the total IG thickness changes according to the data below Note these same dimensions apply wh...

Страница 19: ...factory prepaid by the user and the unit is disclosed to the manufacturers satisfaction to be thus defective This warranty shall not apply to any unit that has been repaired or altered other than by t...

Страница 20: ...1 Low E Coating Table Triple Silver Soft Coat Guardian ClimaGuard 62 67 Cardinal LoE 336 PPG SolarBan 70XL Double Silver Soft Coat Cardinal LoE 240 Guardian ClimaGuard 55 27 PPG SolarBan 67 Guardian C...

Отзывы: