Product Manual — Doc. 8745D
TSS-70 Series • 43
To remove the touch screen after installation, use the included release key to push down on the
security bracket release tabs as shown in the following illustration while gently pulling the touch
screen away from the mounting bracket.
Connect the Touch Screen
Route all necessary cables through the rear of the mounting bracket, and then make connections
to the side of the touch screen rear housing.
Observe the following when connecting the touch screen:
l
Power and data connection is provided to the touch screen by a single Ethernet cable. A
Crestron PoE (Power over Ethernet) power supply, such as the
, or a PoE-
capable network switch is recommended (neither included).
l
The USB ports are used to connect compatible Crestron LED accessories to the touch
screen.
NOTE:
The TSS-770 may use either PoE or PoE+ to supply power to compatible LED
accessories over USB; the TSS-1070 requires at minimum PoE+ to supply power to LED
accessories over USB.
l
Apply power after all connections have been made.