10-Position RJ45 Panel Mount Interface
Crestron
TPSBLOCK-10
NOTE:
The recommended clearance on each
side
of the rectangular
cutout area is approximately 0.268 in (0.681 cm). The clearance at the
bottom
of the cutout area should be approximately 0.180 in (0.457 cm).
The clearance
above
the cutout area is zero.
NOTE:
If affixing a NET/VIDEO or RGB label near the TPSBLOCK-
10 (above or below is recommended), a 0.200 in (0.508 cm) by 0.700 in
(1.778 cm) area is required.
NOTE:
Extron has made available Architectural Adapter Plates (AAPs)
for mounting the TPSBLOCK-10 for Cresnet touchpanel connection.
Refer to “Custom Adapter Plates” on page 5 for details. If using AAPs,
skip steps 2 and 3 in the subsequent procedure.
1. On the panel or desktop pop-up/tilt-up device, determine an
adequate location for the TPSBLOCK-10.
2. Refer to the diagram below. Using the proper tools, cut-out
and remove the rectangular area from the panel or desktop
pop-up/tilt-up device.
TPSBLOCK-10 Installation (1 of 3) - Cutout Diagram
0.675 in
(1.715 cm)
0.590 in
(1.500 cm)
3. Refer to the diagram below. Using an electric drill and
0.136-inch
(#29 or approximately 9/64-inch) drill bit, drill
two TPSBLOCK-10 mounting holes.
TPSBLOCK-10 Installation (2 of 3) - Mounting Hole Diagram
0.143 in
(0.362 cm)
0.276 in
(0.701 cm)
0.136 in
DIAMETER
0.313 in
(0.795 cm)
4. At the inner surface of the panel or desktop pop-up/tilt-up
device, position the female connector of the TPSBLOCK-10
4
•
10-Position RJ45 Panel Mount Interface: TPSBLOCK-10 Installation Guide - DOC. 5979A